Workplace Safety And Health Regulation
168
(i) capable of resisting a force of 22.2
kN in any direction in
which the load may be applied for each worker attached,
and
(ii) made of stainless steel or other material resistant to
corrosion;
(b) the anchorage system is certified by a professional engineer as
having
the required load capacity; and
(c) where an eyebolt is used as an anchor, that the interior opening
of the eye measures at least 38 mm.
Steel frame building requirements
14.28
During the construction
of a steel frame building, the owner of the
building and the prime contractor responsible for the construction
of the building must ensure that the structural components of the
building designed to accommodate
a fall protection system
(a) are designed, approved and certified as safe by a professional
engineer; and
(b) include
(i) double connections at each column
and at beam webs over
a column,
(ii) at least four anchor bolts per column, and
(iii) perimeter columns that extend at least one metre above
the finished floor to permit the installation of perimeter
safety cables.
Dostları ilə paylaş: