Workplace Safety And Health Regulation
339
No internal combustion engines near well
41.18(1) An employer must ensure that an internal combustion engine air
intake or exhaust is located at least 5 m from a well that is open to
the atmosphere or any other source of ignitable vapour.
41.18(2) An employer must ensure that an internal combustion engine located
within 10 m of a well that is open to the atmosphere or any other
source of ignitable vapour has
(a) air intake shut-off valves equipped with a remote control easily
accessible from the operator’s station;
(b) a system for injecting an inert gas into the engine’s cylinders
equipped with a remote control easily accessible from the
operator’s station;
(c) a duct that provides air for the engine from a distance of at
least 10 m from the well or any source of ignitable vapour; or
(d) any other device approved for the purpose of section 37
of the
Drilling and Production Regulation, Manitoba
Regulation 111/94.
41.18(3) An employer must ensure that the exhaust pipe of any internal
combustion engine located within 10 m of a well that is open to the
atmosphere or any other source of ignitable vapour is
(a) directed away from the well or source of ignitable vapour; and
(b) constructed to prevent a flame from emerging along its length
or at its end.