Tn 18A web-nov06. indd


SUMMARY OF RECOMMENDATIONS



Yüklə 324,88 Kb.
Pdf görüntüsü
səhifə2/21
tarix26.12.2016
ölçüsü324,88 Kb.
#3362
1   2   3   4   5   6   7   8   9   ...   21
SUMMARY OF RECOMMENDATIONS:

TECHNICAL NOTES

 on Brick Construction

18A

November 

2006

1850 Centennial Park Drive, Reston, Virginia 20191 



|

 

www.gobrick.com | 

703-620-0010

Vertical Expansion Joints in Brick Veneer:

• For brickwork without openings, space no more than 25 ft 

(7.6 m) o.c.

• For brickwork with multiple openings, consider symmetrical 

placement of expansion joints and reduced spacing of no 

more than 20 ft (6.1 m) o.c.

• When spacing between vertical expansion joints in para-

pets is more than 15 ft (4.6 m), make expansion joints 

wider or place additional expansion joints halfway between 

full-height expansion joints

• Place as follows:

  - at or near corners

  - at offsets and setbacks

  - at wall intersections

  - at changes in wall height

  - where wall backing system changes

  - where support of brick veneer changes

  - where wall function or climatic exposure changes

• Extend to top of brickwork, including parapets 