Ruxsat etilgan ishchi yuklanishning qiymatlari [R0], MPa.
Tasma
Turi
|
Dmin/
|
20
|
25
|
30
|
35
|
40
|
45
|
50
|
60
|
75
|
100
|
CHarm tasma
|
1,4
|
1,7
|
1,9
|
2,04
|
2,15
|
2,23
|
2,3
|
2,5
|
2,5
|
2,6
|
Rezina matoli
Tasma
|
1,35
|
1,5
|
1,6
|
1,67
|
1,72
|
1,77
|
1,8
|
1,85
|
1,9
|
1,95
|
Ip gazlamali tasma
|
1,35
|
1,5
|
1,6
|
1,67
|
1,72
|
1,77
|
1,8
|
1,85
|
1,9
|
1,95
|
Eslatma: Jadval P0 = 1,8 N/mm qilib olingan hol uchun tuzilgan. Agar P0 = 2,0 N/mm qilib olinsa, [P0] ning qiymati jadvaldagidan 10% ko’p qilib olinadi; agar shkivlar plastmassalardan tayyorlangan bo’lsa, 20% ga oshiriladi; nam va changli sharoitda ishlaydigan uzatmalar uchun 10-30 % ga kamaytiriladi. P0 – tasmaning dastlabki tarangligidan hosil bo’ladigan ishchi yuklanish.
C - qamrov burchagining uzatma tortish qibiliyatiga ta’sirini inobatga oluvchi koeffitsient bo’lib, quyidagi formula orqali aniqlaniladi yoki 7-jadvaldan tanlanadi;
(18)
7-jadval
01
|
150
|
160
|
170
|
180
|
200
|
220
|
S
|
0,91
|
0,94
|
0,97
|
1,0
|
1,1
|
1,2
|
C- tezlikni uzatma ishiga ta’sirini hisobga oluvchi koeffitsient bo’lib, quyidagi formula orqali aniqlaniladi yoki 8-jadvaldan tanlanadi;
(19)
8-jadval
m/s
|
5
|
10
|
15
|
20
|
25
|
30
|
S
|
1,03
|
1,00
|
0,95
|
0,86
|
0,79
|
0,68
|
Cr- ishlash rejimini hisobga oluvchi koeffitsient bo’lib, 9-jadvaldan tanlanadi (Sr=1).
9-jadval
-
Yuklanish xarakteri
|
Mashina turi
|
Cr
|
Yuklanish tekis ta’sir etuvchi hollar
|
Ventilyatorning markazdan qochirma nasos va kompressorlar, tokarlik va parmalash dastgohlari
|
1,0
|
Yuklanishning o’zgarishi mehyorida bo’lgan hollar
|
Porshenli nasos va kompressorlar, plastinali transportyorlar avtomat dastgohlar
|
0,9
|
Yuklanishning o’zgarishi sezilarli darajada katta bo’lgan hollar
|
Harakat yo’nalishi qarama-qarshi tomonga o’zgarib turadigan yuritma-lar, randalash dastgohlari, elevatorlar
|
0,8
|
Yuklanishning o’zgarishi notekis bo’lgan va zarb bilan ta’sir qilgan hollar
|
Ko’targichlar, ekskavatorlar, presslash mashinalari, bolg’alash uskunalari va shu kabilar
|
0,7
|
C0-taranglash usuli va uzatmaning gorizontal tekislikka nisbatan joylashuvini hisobga oluvchi koeffitsient bo’lib, 10-jadvaldan tanlanadi (C0=1).
10-jadval
-
Tasmali uzatmaning turi
|
Uzatmaning gorizontal tekislikka nisbatan joylashuv burchagi
|
00-600
|
600-800
|
800-900
|
Tasmaning tarangligi avtomatik ravishda tahminlanadigan uzatmalar
|
1,0
|
1,0
|
1,0
|
Ochiq va taranglovchi moslamasi bo’lgan uzatmalar
|
1,0
|
0,9
|
0,8
|
Ayqash uzatmalar
|
0,9
|
0,8
|
0,7
|
Yarim ayqash va yo’naltiruvchi rolikli uzatmalar
|
0,8
|
0,7
|
0,6
|
12. Uzatmada hosil bo’ladigan kuchlarni aniqlash:
a) yuqorida tahkidlanganidek tasma shkivlarga mahlum taranglik bilan kiydiriladi. Bunda yuklanishsiz dastlab faqat taranglik kuchi F0 mavjud bo’ladi:
(20)
Bu yerda σ0=1.8 MPa bo’lib dastlabki taranglik kuchidan hosil bo’ladigan kuchlanishdir;
δ – tasmaning qalinligi, tasma materialiga ko’ra 1, 2, 3 – jadvallardan tanlanadi;
Tasmaning qalinligi tanlashda quyidagi shart bajarilishi kerak, mm
b - tasmaning eni bo’lib, quyidagi formula orqali aniqlaniladi va hisobiy qiymat GOST qiymatga taqqoslanilib, tasma materialiga ko’ra 1, 2, 3- jadvallardan tanlanadi, δ =5 mm, Z=4
(21)
Aniqlangan qiymat bo’yicha tasmaning eni 1, 2, 3- jadvallardan tanlanadi b = 125 mm.
b) aylana kuch – Ft ;
(22)
v) Yetaklovchi va yetaklanuvchi tarmoqlarning taranglik kuchi F1, F2 (markazdan qochma kuchning tasma tarangligiga ta’siri hisobga olinmagan) (2-shakl);
(23)
1-jadval
rezina to’qimali tasmalarning o’lchamlari
/GOST 23831-79/
Tasmalarning eni
b, mm
|
Qatlam soni
|
Tasmalar qalinligi
, mm
|
qatlamligi
|
Qatlamsizi
|
20, 25, 32, 40, 50, 63, 71, 80, 90, 100, 112
|
3
|
4,5
|
3,75
|
20, 25, 32, 40, 50, 63, 71, 80, 90, 100, 112,
120, 125, 140, 160, 180, 200, 224, 250, 280
|
4
|
5
|
5
|
20, 25, 32, 40, 50, 63, 71, 80, 90, 100, 112, 120, 125, 140, 160, 180, 200, 224, 250, 280, 315, 355
|
5
|
7,5
|
6,25
|
80, 90, 100, 112, 120, 125, 140, 160, 180, 200, 224, 250, 280, 315, 355, 400, 450, 500
|
6
|
9,0
|
7,5
|
2-jadval
CHarm tasmalarning o’lchamlari
/GOST 18697-73/
Tasmalarning eni
b, mm
|
Tasmalarning qalinligi -,mm
|
Bir qatlamligi
|
Ikki qatlamligi
|
10,16,20,25
|
3,0...3,5
|
-
|
32,40,50
|
3,5...4,0
|
-
|
63,71
|
4,0...4,5
|
-
|
80,90,100,112
|
4,5...5,0
|
7,5...8,0
|
125,140
|
5,0...5,5
|
9,0...9,5
|
160, 180, 200, 224, 250, 280, 355, 400, 450, 500, 560
|
5,5...6,0
|
9,5...10,0
|
3-jadval
Ip gazlamali tasmalarning o’lchamlari
/GOST 6982-75/
Tasmalarning eni
b, mm
|
Tasmalarning qalinligi -, mm
|
Qatlamlar soni
|
30, 40, 50, 60, 75, 100
|
4,5
|
4
|
30, 40, 50, 60, 75, 90, 100, 115, 125, 150, 175
|
6,5
|
6
|
50, 75, 90, 100, 115, 125, 150, 175, 200, 225, 250
|
8,5
|
8
|
4-jadval
Yassi tasmalarning texnikaviy tavsifi
Asosiy ko’rsatkichlar
|
Tasmaning turi
|
CHarm tasma
|
Rezina matoli tasma
|
Ip gazlamali tasma
|
GOST
|
18697-73
|
23831-79
|
6982-75
|
Tavsiya etiladigan eng katta tezlik, m/s
|
45
|
30
|
20
|
Dmin/
nisbatning
|
Tavsiya etilgani
|
35
|
40
|
30
|
Ruxsat etilgani
|
25
|
30
|
25
|
Mustahkalik chegarasi, MPa
|
200-250
|
37-44
|
50
|
Elastiklik moduli Ye,MPa
|
100-150
|
100-200
|
50-80
|
5-jadval
Yassi tasmali uzatma shkivlarining o’lchamlari, mm /GOST 17383-73/
SHkiv diametrlari (mm)
40, 45, 56, 63, 71, 80, 90, 100, 112, 125, 140, 160, 180, 200, 224, 250, 280, 315, 355, 400, 450, 500, 560, 630, 710, 800, 900, 1000, 1120, 1250, 1400, 1600, 1800, 2000
|
Tasma-ning
eni
v
|
SHkiv gardishi-ning eni
V
|
SHkiv qaba-riqligining
balandligi
h
|
Tasma-ning
eni
v
|
SHkiv gardishi-ning eni
V
|
SHkiv qabariq-ligining
balandligi
h
|
30
|
40
|
1.0
|
80
|
100
|
1.5
|
40
|
50
|
85
|
100
|
50
|
60
|
90
|
100
|
60
|
70
|
1.5
|
|
|
2.0
|
g) shkiv valiga ta’sir etuvchi kuch FB ;
(24)
13.Tasmadagi kuchlanishlarni aniqlash:
a) Eng katta kuchlanish Yetaklovchi tarmoqda bo’lib, F1 kuchi ta’sirida
hosil bo’lgan σ1 kuchlanishidir;
, (25)
b) Tasmaning shkivni qamrab turgan joyida hosil bo’lgan eguvchi kuchlanish;
(26)
E-tasma materialning elastiklik moduli bo’lib, 4-jadvaldan olindi (E=100 MPa).
Kapronli tasmalar uchun esa E=600 MPa deb qabul qilinadi.
v) Markazdan qochma kuch ta’sirida hosil bo’ladigan σv kuchlanish;
(27)
ρ – tasma zichligi bo’lib, rezina-mato-chilvirli tasmalar uchun 1100-1200 kg/m3, charmli tasmalar uchun 1000-1100 kg/m3 , ip gazlamali tasmalar uchun 900-1000 kg/m3 .
g) Maksimal kuchlanish esa,
(28)
Maksimal kuchlanishning hisobiy qiymati doimo rezina-matoli va charmli tasmalar uchun chegaraviy kuchlanish σ-1 ≤ 7 MPa dan , ip gazlamali tasmalar uchun esa σ-1 ≤ 5 MPa dan oshmasligi shart. σ-1 ≤ 7 MPa
14. Tasmani uzoq ishlash muddatiga tekshirish;
(29)
Ci - uzatishlar nisbatini inobatga oluvchi koeffitsent;
CH – tasma yuklanishini inobatga oluvchi koeffitsenti, yuklanish davriy o’zgarish davrida (noldan maksimumgacha) CH=2 bo’lib, doimiy yuklanish davrida esa CH=1 ga teng bo’ladi; (CH =1)
- tasmaning sekundiga aylanishlar soni.
λ ni aniqlaganda L ning qiymatini mm dan metrga o’tkazib xisoblaymiz
Dostları ilə paylaş: |