Regime

Description

A

Unsubmerged entrance and exit. Critical flow at entrance. Upstream controlled.

B

Submerged entrance and unsubmerged exit. Orifice flow at entrance. Upstream controlled. For circular culverts, only available in Method B.

C

Unsubmerged entrance and exit. Critical flow at exit. Upstream controlled.

D

Unsubmerged entrance and exit. Sub-critical flow at exit. Downstream controlled.

E

Submerged entrance and unsubmerged exit. Full pipe flow. Upstream controlled.

F

Submerged entrance and exit. Full pipe flow. Downstream controlled.

G

No flow. Dry or flap-gate active.

H

Submerged entrance and unsubmerged exit. Adverse slope. Downstream controlled.

J

Unsubmerged entrance and exit. Adverse slope. Downstream controlled.

K

Unsubmerged entrance and submerged exit. Critical flow at entrance. Upstream controlled. Hydraulic jump along culvert. Method B only.

L

Submerged entrance and exit. Orifice flow at entrance. Upstream controlled. Hydraulic jump along culvert. Method B only.

Figure 4.8 1D Inlet Control Culvert Flow Regimes



Figure 4.9 1D Outlet Control Culvert Flow Regimes