positive-isolation

4.4.1.  Single Valve Isolation 

  Single valve isolations may only be used in the following circumstances unless an 

engineering assessment is completed as required in Section 4.0 above: 

o

 



Opening equipment to establish positive isolation (i.e., install blinds). 


 

POSITIVE ISOLATION

 

 

Rev Date:  March 2015 



Page 6 of 8 

This document is uncontrolled when printed.

 

Canada 



o

 

Pig sending and receiving during routine operations 



  When a single valve isolation is used, the following conditions must be satisfied: 

o

 



The isolation is not left unattended 

o

 



The isolation is not for confined space 

o

 



The isolation is not for hot work 