4 LAB

Material Type
Material
Feeder Segment
Temination Material
Optical Distribution Frame
ODC
Cable
FO Duct G.652.D
FO Aerial G.652.D
Other
Splitter 1:4
Pathcored
Connector
Distribusi
Segment
Temination Material
ODP
Cable
FO Duct G.652.D
FO Aerial G.652.D
Other
Splitter 1:8
Connector
Drop Segment
Temination Material
OTP
Cable
FO Duct G.657.A
FO Aerial G.657.A
Other
Connector
Klam
Indoor Segment
Temination Material
ONT/ONU
cable
Drop Indoor G.657.A
other
Connector
Patchcord
UTP, PVC, Coaxial cables
The maximum length of feeder cable for RING configuration is 20 km. Max 2 stage splitter with 1
core feeder. Maximum to 32 Home Pass / More in accordance with the link budget obtained. The type
of connector used per element is SC-UPC. The type of pole used for aerial systems can use concrete or
steel poles along with their respective accessories. In the FTTH configuration, there are several main
devices. The first is the Optical Line Termination (OLT) that serves as the end-point of the passive
optical network service. OLT provides an interface between Passive Optical Network (PON) systems
with service providers (data service, video, or voice / phone). The second device is ODC (Optical
Distribution Cabinet). ODC is a passive device that is installed outside STO (outdoor) and can also be
indoors or in MDF (indoor). ODC serves as a splitter or distribution point of the feeder cable into a
distribution cable.
The third device is the ODP (Optical Distribution Point) which is a device that divides the distribution
cable into a drop cable using a 1: 8 splitter. And the fourth device is the ONU (Optical Network Unit)
which is the device installed at the customer side.
The distance used in this research reaches the maximum distance that the PT. Telkom Access
standard is 17 Km. shown in figure 3. Feeder cable from STO minimum 288 core capacity for both duct
and aerial system with cable type G.652.D. While the type is loose tube (max 2x288 core) or ribbon
cable (> 288 cores). The configuration used is downstream and upstream with one way simulation. For
downstream, passive splitter used is a ratio of 1: 4 on ODC so that from 1 pieces OLT cores can distribute
light signals up to 32 ONT / ONU at once. The light signal from 1 ODP is transmitted to 8 ONT by
using a passive splitter of 1: 8. The configuration of upstream is shown in Figure 4.


5
1234567890
‘’“”
International Symposium on Materials and Electrical Engineering (ISMEE) 2017 
IOP Publishing
IOP Conf. Series: Materials Science and Engineering 

Yüklə 0,89 Mb.

Dostları ilə paylaş:
1   2   3   4   5   6   7   8   9   10   11




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©azkurs.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin