1. Remove the battery cover by placing your thumb on the indented portion on the rear



Yüklə 0,62 Mb.
Pdf görüntüsü
səhifə4/4
tarix20.11.2023
ölçüsü0,62 Mb.
#162530
1   2   3   4
help truescience quick online v21

4. REGISTER THE SMART QR BUFFERS
1. The electrode must
be calibrated before
use. Touch the red
“UNCALIBRATED”
message at the
bottom of the screen
to begin.
2. The calibration
screen opens. The
buffers must be
added first, touch the
+ icon in the white bar
at the top of the
screen to add buffers.
3. The inventory is
shown but there
are currently no
buffers in the
inventory. Touch
the red + icon to
add the buffers.
4. Add buffers either
from the lists of
standard or custom
buffers, or touch the
“tap to scan” icon to
quickly add QR
TRUEscience buffers.
5. The QR scanner
opens, point the
camera on your
device at the QR
code on the buffer
and hold steady for
2 seconds to allow it
to scan.
6. When the buffer has
been recognised, the
information and
documents are
shown. View the
MSDS or certificates
of analysis specific to
this buffer by
touching the relevant
fields here. Touch
“SAVE” to finish.
7. The buffer is added
to the inventory
and the App will
now remind you
when it is expiring.
Note: if you have
manually added
buffers without
adding the expiry
date you will not
get an expiry
reminder.
8. Add the other
buffers in the same
way. All will be
added to the list.
You are now ready
to calibrate the
electrode. To delete
a buffer press on
the buffer’s colour
square and swipe
right.


“tap to scan” icon to 
1. Pour a small amount
of each buffer into
separate beakers and
rinse your electrode
with de-ionised water
and then touch the
green play icon to
begin.
2. Place the electrode in
the buffer highlighted
on screen and stir
gently. Stop stirring to
allow reading to
stabilise.
3. Once the reading is
stable, the 
SAVE
icon turns green:
Touch the 
SAVE
icon
to save the 
calibration
point and 
move on to
the next 
highlighted
buffer.
4. Repeat until all
buffers have been
used. Rinse the
electrode between
each reading. If icon
does not turn green
replace your buffers
and ensure your rinse
step is adequate.
5. Once all buffers
have been used a
message will
appear showing
the completed
calibration results
and electrode
health. Touch
“KEEP” to save the
calibration and
return to the
calibration screen.
6. Touch “METER” to
return to the meter
view. We can now
see the live reading
and can see the
electrode is
connected and
calibrated. You can
now begin testing.
The App will remind
you when the next
calibration is due.
5. CALIBRATE THE ELECTRODE


ACCESSORIES AND SPECIFICATIONS
WWW.TRUESCIENCE.CO.UK
Combination pH electrode glass with S7 connector 
1201575 
Combination pH electrode double junction flat with S7 connector
1201574
Combination pH electrode double junction epoxy with S7 connector 
1201711
Replacement Lithium battery for SMART Cap 
1201564
Spare battery covers colour coded Grey, Teal, Red (Set of 3)
1201710
Spare battery covers colour coded White, Teal, Red (Set of 3) 
1201813
Tablet 7”/ 8” Bluetooth® enabled Android 
1201708
Storage Stand (includes storage tubes) 
1201695
Spare storage tubes for storage stand (Pack of 2) 
1201696
Charging tablet stand includes USB Cable 
1201562
Height adjustable tablet stand, Stainless steel, non-charging 
1201563
Replacement SMART Clip 
1201698
Additional SMART Cap (supplied withbattery and 3x colour coded covers, without electrode) 1201689
250ml
 
500ml
1000ml
Buffer solution pH 4.00 ± 0.01 @ 20°C Red
1201459 
1144885 
1144887
Buffer solution pH 7.00 ± 0.01 @ 20°C Yellow 
1201458 
1144955 
1144960 
Buffer solution pH 10.00 ± 0.01 @ 20°C Blue
1201460
1145008 
1145011 
pH electrode storage solution 
-
1145514
-
Electrode cleaning solution (pepsin/hydrochloric) 
-
1145463
-
TECHNICAL SPECIFICATION
pH Range
0-14 pH units
Resolution
0.01pH , 0.1mV, 0.1°C
Meter Precision
±0.002pH
Electrode accuracy 
±0.02pH
Calibration points 
up to 5 points 
Buffer Recognition 
QR Code Input 
Automatic temperature compensation 
0°C - 100.0°C
Electrode diagnostics
Yes
mV range
±1000mV
mV accuracy
±0.1mV
Temperature accuracy 
±0.5°C
Store values
10,000 measurements/log
Battery Life
1 year normal use
Battery Type
1/2 AA Lithium Thionyl Chloride, 3.6V, 1200mA
Tablet and App requirements 
See above or specified list of tested models on our website 
Dimensions of Cap 
W48 x D24 x L218 mm including temperature probe 
Temperature probe length
130mm long
Weight
91.5 g
Operating/Storage Temperature
0-55°C
Calibration Certainty 
Yes, App indicates calibration status, time and date
Electrode health reminders
Yes
Colour keyed battery covers
Yes
Multiple Cap Measurements 
Yes, up to 6 simultaneously
Consumables ordering online 
Yes
Compatible with any S7 connector pH electrode 
Yes
Interval logging
Yes
Tablet Requirements:
The TRUEscience App has been designed with responsive screensso is suitable 
for a wide range of Android phones and tablets. Bluetooth® 4.0 or later and Android 4.4 or later are 
required. You will require a WiFi connection for data sharing and full App functionality. The App will run in 
the background and will require access to GPS, Camera, Bluetooth® and sharing Apps such as GMail, 
Dropbox and Googledrive.
EN61236-1:2006 - Annex A and B 2008: 1999/5/EC Annex III - Complies with R&TTE Directive 1999/5/EC 
and RoHS recast directive 2011/65/EU
Contains transmitter module FCC ID:QOQBLE113. The Bluetooth® transceiver device meets the requirement for 
modular transmitter approval as detailed in FCC public notice DA00-1407
v1.0 10/16
Multiple patents pending
Patents
FCC

Document Outline

  • Truescience Quick Online p1v2
  • Truescience Quick Online p2v2
  • Truescience Quick Online p3v2
  • Truescience Quick Online p4v2
  • Truescience Quick Online p5v2
  • Truescience Quick Online p6v2

Yüklə 0,62 Mb.

Dostları ilə paylaş:
1   2   3   4




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©azkurs.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin