Horizontal Expansion Joints in Brick Veneer:
• Locate immediately below shelf angles
• Minimum ¼ in. (6.4 mm) space or compressible material
recommended below shelf angle
• For brick infill, place between the top of brickwork and
structural frame
Brickwork Without Shelf Angles:
• Accommodate brickwork movement by:
- placing expansion joints around elements that are rigidly
attached to the frame and project into the veneer, such
as windows and door frames
- installing metal caps or copings that allow independent
vertical movement of wythes
- installing jamb receptors that allow independent
movement between the brick and window frame
- installing adjustable anchors or ties
Dostları ilə paylaş: |