0027-nd rev 11.2 8-jul-16 guidelines for marine lifting and lowering operations

GUIDELINES
 
FOR
 
MARINE
 
LIFTING
 
&
 
LOWERING
 
OPERATIONS 
0027/ND Rev 11 
 
Page 26 of 84 
If the stated conditions are not met, the SKL should normally be found by calculation. However, 
generally if the length tolerance is stricter than stated, the minimum axial load requirement in the 
spreader bars could be relaxed. 
5.6.7 
For lifts where more than two hooks are used and each hook is connected to a single spreader bar, a 
SKL of 1.1 should be used. A reduced value may be justified provided the hook elevations can be 
shown to be individually controlled and subject to evaluation of sling length tolerances, the rigging 
arrangement and crane operating procedures.
5.6.8 
For indeterminate 4-sling lifts using matched pairs of cable laid slings or grommets, a Skew Load 
Factor (SKL) of 1.25 shall be applied to each diagonally opposite pair of lift points in turn provided the 
following are applicable: 
For Slings: 

The slings are fabricated with a length tolerance of ±1.5d and the difference between a 
matched pair of slings shall not be more than 0.5d where d is the sling diameter. 

The slings are of a standard construction and meet the criteria of 160xW/d2 <1.0 where W is 
the weight in kilograms (kg) per metre (m) of the sling and d is the sling diameter. 

The slings are installed so that the longer slings of each matched pair are not on the same 
diagonal. 

Sling utilisation when checking with the termination factor (see Sections 7.3.1 and 7.7.1) and 
a skew factor of 1.25 should be more than 0.6.
For Grommets: 

The grommets are fabricated with a circumferential length tolerance of ±3.0d and the 
difference between a matched pair of grommets shall not be more than 1.0d where d is the 
grommet diameter. 

The grommets are of a standard construction and meet the criteria of 160xW/d2 <1.0 where 
W is the weight in kilograms (kg) per metre (m) of the each leg of the grommet and d is the 
grommet diameter. 

The grommets are installed so that the longer grommets of each matched pair are not on the 
same diagonal. 

Grommet utilisation when checking with a termination factor of 1.0 (see Sections 7.3.1 and 
7.6.1) and a skew factor of 1.25 should be more than 0.6.
Note: where sling or grommet utilisations are less than 0.6, whilst a higher skew factor will not overload 
the slings/grommets, the load on the lift point may increase and the effect of this shall be included in 
the design for the lift points. 
5.6.9 
In lieu of the skew factors used in Section 5.6.8, the actual skew factor may be determined using a 
more detailed analysis allowing for actual rigging properties, extreme tolerances for new build rigging, 
and hook rotation. Where possible, the analysis should include the lifted structure so that the effect of 
the structure’s stiffness can be considered or where this is not carried out, the structure can be 
considered infinitely stiff and thus offers no reduction to the skew value determined. 
5.6.10 
For indeterminate 4-sling lifts using four cable laid slings of un-equal length, the skew load shall be 
calculated using an elastic modulus, E, of 25,000 N/mm
2
with the sling area used based on a value of 
0.785 x d
2
, where d is the sling diameter in mm, and the sling lengths based on the most onerous 
fabrication tolerances.
5.6.11 
For indeterminate 4-grommet lift using four cable laid grommets of un-equal length, the skew load shall 
be calculated using an elastic modulus, E, of 25,000 N/mm
2
with the grommet area used based on a 
value of 1.57 x d
2
, where d is the diameter in mm of one leg of the grommet, and the grommet lengths 
based on the most onerous fabrication tolerances.
11 



Yüklə 1,31 Mb.

Dostları ilə paylaş:
1   ...   20   21   22   23   24   25   26   27   ...   97




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©azkurs.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin