GUIDELINES
FOR
MARINE
LIFTING
&
LOWERING
OPERATIONS
0027/ND Rev 11
Page 59 of 84
17
BUMPERS AND GUIDES
17.1
INTRODUCTION
17.1.1
For module installation the arrangement and design philosophy for bumpers and guides shall be
submitted, where applicable. In general, bumpers and guides should be designed in accordance with
this Section taking
into account of their use, configuration and geometry.
17.2
MODULE MOVEMENT
17.2.1
The maximum module movement relative to the target structure during installation should be defined.
In general, the relative motions should be limited to:
Vertical movement: +/- 0.75
metres
Horizontal movement: +/- 1.50 metres
Longitudinal tilt:
2
degrees
Transverse tilt:
2 degrees
Plan rotation:
3 degrees.
17.2.2
The plan rotation limit is only applicable prior to engagement on the bumper/guide or pin/bucket
system, and when the module is close to its final position or adjacent to another structure on a cargo
barge.
17.2.3
Special consideration and agreement of relative motions with GL Noble Denton is required for cases
where a module is being placed onto a floating target structure, as the motions of the target structure
need to be considered.
Dostları ilə paylaş: