PUMPS GENERAL CHARACTERIZATION 

Pumps  are  rotating  equipment  to  increase  liquid  pressure  for  transporting  from  one  place  to 

another. There are two categories of pumps: dynamic(kinetic) and positive displacement.                                                                                              

 

                        



               

                                                     Table 7.1:  Pumps classification 



 

Pump  selection  is  made  on  the  flow  rate  and  head  required,  together  with  other  process 

considerations, such as liquid density, viscosity and corrosivity; the presence of solids or entrained 

gases in the fluid.  

Viscosity  have  significant  effect  on  performance  of  centrifugal  pumps.  For  highly  viscous  fluids 

positive displacement pumps are the best choice. 

Solid-liquid slurries cause particular problems for all rotating pumps. A special slurry pump with 

low speed is supposed to be used. 

If the liquid contains small amount of gases, positive displacement pumps are more appropriate. 

Since  erosion  is  natural  companion  of  corrosion,  lower  velocity  is  essential  for  highly  corrosive 

liquids.  

The selection of the pump cannot be separated from the design of the complete piping system. 

The total head required will be the sum of the dynamic head due to friction losses in the piping, 

fittings, valves and process equipment, and any static head due to differences in elevation. 

The pressure drop required across a control valve will be a function of the valve design. Sufficient 

pressure drop must be allowed for when sizing the pump to ensure that the control valve operates 

satisfactorily over the full range of flow required. If possible, the control valve and pump should be 

sized together, as a unit, to ensure that the optimum size is selected for both. 

 

 

 



 

 