Installation Guide: IntelliFlo3 and IntelliPro3 vsf pool Pump


WHEN THE PUMP IS CONNECTED TO AUTOMATION



Yüklə 6,98 Mb.
Pdf görüntüsü
səhifə14/37
tarix16.12.2023
ölçüsü6,98 Mb.
#182724
1   ...   10   11   12   13   14   15   16   17   ...   37
intelliflo3-pro3-vsf-install-guide

WHEN THE PUMP IS CONNECTED TO AUTOMATION:
• CONNECT LED will pulse Magenta/Pink
• Touchscreen Controller (if installed) will display a message indicating the pump is being controlled by an 
automation system
• 
Pentair Home app will display a message confirming the pump is being controlled by an automation system
• All pump control is handled by the automation system
• When putting the automation mode into Service Mode, the automation system will return control to the pump
An IntelliTouch Automation System with firmware 1.170 or earlier will display "VSF+SVRS" in the pump type/
selection. While you will choose this option
the pump does NOT incorporate SVRS entrapment protection.
If operating the pump with a Pentair automation system, when the pump is disconnected from automation 
or in service mode it will continue operating according to the factory default programs/schedules. Ensure 
programs/schedules are edited or disabled before servicing the pump.
DEVICE / L2
SUPPLY / L2
SUPPLY / L1
 DEVICE / L1
16A MAX
5A MAX
DEVICE / L2
SUPPLY / L2
SUPPLY / L1
 DEVICE / L1
VOUT
OUTPUT FOR D.I. TRIGGER (+12V) 
SP4
SPEED 4 DIGITAL INPUT (5-30 VAC/DC)
SP1
SPEED 1 DIGITAL INPUT (5-30 VAC/DC)
SP2
SPEED 2 DIGITAL INPUT (5-30 VAC/DC)
SP3
SPEED 3 DIGITAL INPUT (5-30 VAC/DC)
GND
GROUND
DIGITAL INPUT WIRING
**
Note
:
Digital Input and Pump Relay 
connections are only available if the 
optional Relay Control Board (P/N 
356365z) is installed.
Refer to 
Relay Control Board Digital 