14
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation and Maintenance Guide
MAINTENANCE
Cleaning the Pump Strainer Basket
The strainer pot is located at the front of the pump and
houses the pump strainer basket.
The strainer basket can be viewed through the strainer
pot lid and should be visually inspected at least once
a week. Regularly emptying
and cleaning the strainer
basket will lead to higher filter and heater efficiency and
prevent unnecessary stress on the pump motor.
TO CLEAN THE STRAINER BASKET:
1.
Press ON/STOP to stop the pump and disconnect
all power to the pump at the circuit breaker.
2.
Open the filter's air relief valve and relieve all
pressure from the filtration system.
3. Turn the strainer pot
lid counter-clockwise and
remove it from the pump.
4. Remove the strainer basket and rinse out all debris.
Replace the basket if it is cracked or damaged.
5. Place the strainer basket back into the strainer pot.
Ensure the opening in the front of the strainer basket
is aligned with the suction outlet.
6. Fill the strainer pot up to the suction port with water.
7. Clean the lid O-ring and sealing surface of the
strainer pot.
Note:
It is important to keep the lid O-ring clean.
8. Reinstall the lid by placing it onto the strainer pot
and tightening clockwise until the lid handles are
perpendicular to the suction port.
Note:
Ensure the lid O-ring
is properly placed and
is not being pinched between the lid and strainer
pot.
9.
Open the filter air relief valve and stand clear of the
filter.
10. Reestablish power to the pump at the circuit breaker
and start the pump.
11.
When a steady stream of
water flows from the filter
air relief valve, close the valve.
Winterizing
Do NOT rely solely on Thermal Mode to protect
your filtration system from freezing temperatures.
Thermal Mode is based on the internal drive temperature and may not
reflect actual air temperature.
You are responsible for
determining when freezing
conditions may occur. If freezing conditions are
expected, take the following steps to reduce the risk of
freeze damage.
Freeze damage is not covered under
warranty.
In
mild climate areas, when temporary freezing
conditions may occur, run your filtering equipment all
night to prevent freezing.
Dostları ilə paylaş: