18
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation
and Maintenance Guide
Drive Removal and Installation
TO DISASSEMBLE AND REMOVE THE DRIVE:
1.
Press ON/STOP to stop the pump and
disconnect all power to the pump at the circuit
breaker.
2. Loosen the two captive Phillips-head Wiring
Cover Screws. Remove the Wiring Cover from
the Drive.
3. Disconnect main power wiring and remove the
Automation Terminal Blocks from the drive.
4. Remove the four Phillips-head Drive Cover
Screws. Remove the Drive Cover from the
Drive.
5. Remove the four Phillips-head Drive-to-Motor
Screws.
6. Gently separate the Drive from the Motor/
Hydraulic Assembly and place it aside.
TO INSTALL THE DRIVE:
1. Ensure the drive
connection gasket is not
damaged and is in place.
Do not reassemble
with a damaged or missing
gasket. Replace the gasket if damaged.
2. Align the Drive with the Drive Connection and seat the drive onto the motor.
3. Secure the Drive to the motor with the four Drive to Motor Screws.
4. Reinstall the Drive Cover and secure it with the four Drive Cover Screws.
5. Rewire automation and power cables that were disconnected during drive removal.
Refer to
Electrical Installation,
page 3
and
Connecting to an Automation System, page 4
.
6. Reinstall the Wiring Cover and secure it with the two Wiring Cover Screws.
Dostları ilə paylaş: