1- Device Type:
Select the device connected to a 
particular relay. 
• RELAY 1 Options:
Lights, Salt Cell or Other
• RELAY 2 Options: 
Lights, Salt Cell, Booster 
Pump or Other
Note:
If a relay is designated "Booster Pump", the 
pump will first ensure the Booster Pump has water 
by delaying power to the relay until the pump has 
run for two minutes.
If the pump is already running a program then there 
will be no delay. 
2− Device Nickname:
Enter the name you want your device to display on Program Setup screens.
3− Speed/Flow Dependent:
Check this box to ensure the relay is only activated when the pump is running.
Priming Parameters
Pump Dashboard ˃ Device Settings ˃ Priming Parameters
All priming settings can be edited and set from this screen.
Tap EDIT to view and edit the following priming 
settings:
1- Enabled/Disabled:
ENABLED allows the pump to 
detect whether or not the system is properly primed 
for pump startup.
If prime is not detected the pump will enter a 
priming cycle, based on the settings below.
2− Priming Speed:
Set the speed the pump will run 
during a priming cycle. 
3− Max Priming Duration:
Set the maximum amount 
of time the pump will attempt to prime.
If the pump does not achieve prime during this time 
a priming error will display and the pump will stop.
4− Priming Range:
Set the sensitivity of pump prime detection.
Lower settings require higher flow to detect a successful prime. 
5− Priming Delay:
Set the amount of time the pump remains at priming speed before transitioning to the 
selected program.
6− Loss of Prime:
ENABLED allows the pump to detect low-flow or no-flow situations while running.
If a loss of prime is detected the pump will pause and attempt to prime, based on the settings above. If 
priming is successful the pump will continue programmed operation.