MIXING:
Mix and use one complete unit at a time. Do
not sub-divide.
Gun grade is supplied in base & catalyst in
separate units.
Mix for 5 - 10 minutes using a suitable paddle
fitted to a 500 rpm electric drill moving the
paddle completely through the mass of the
material.
Add the complete contents of the catalyst from
its container and mix thoroughly, into the base
using a palette knife.
Failure to completely disperse catalyst
throughout the base compound will result in
uncured sealant. Once mixed
MasterSeal GG 470 should be used
immediately.
APPLICATION
MasterSeal GG 470 is formulated to be
applied using a sealant gun but may be
applied by trowel if required.
Sealant guns are fitted with conical nozzles
which can be cut to suit the joint width.
The sealant should be gunned into the joint
using an even trigger pressure, cleaning the
nozzle occasionally to avoid contamination.
Deep joints should be filled in two or more
runs, to prevent air entrapment.
Once the sealant has been applied, a small
timber spatula, soaked in soapy water, should
be used to compact the sealant into the joints
and to achieve a smooth polished finish. Any
masking tape which has been applied should
be removed before the sealant cures.
Mixing and application equipment should be
cleaned immediately.