Disclaimer notice



Yüklə 34,51 Kb.
Pdf görüntüsü
tarix01.01.2017
ölçüsü34,51 Kb.
#3963

 

 

 



                ISO 9001 / AS9100 Certified  

 

28570 Livingston Avenue, Valencia, CA 91355-4171  



  (661) 257-1677   FAX (661) 257-8939 

 

TECHNICAL DATA & INFORMATION 

- DISCLAIMER NOTICE - 

All statements, technical data, and recommendations expressed herein are based on tests believed to be reliable and accurate.  However, APTEK LABORATORIES, INC. gives no warranty, 

expressed or implied, regarding the accuracy of this information.  It is intended that the buyer and user of these products shall determine the suitability of the  information provided for his 

specific application, and is responsible for its selection. 

 

APTEK LABORATORIES, INC. shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use or misuse of these products, or of the information given in these 



data bulletins.  Purchasers assume all risk and liability whatsoever in connection with the use of these products and this information. 

 

APTEK



®

 6110-A/B 

Optoelectronic Encapsulant 

 

PRODUCT DESCRIPTION 

 

APTEK 6110-A/B is a two component, unfilled, water clear, tough system designed for the encapsulation of LED chips 

in optoelectronic devices.  APTEK 6110-A/B provides excellent environmental protection and when casted becomes 

the lens portion of the device and displays excellent clarity and light transmissivity.  APTEK 6110-A/B was formulated 

to display minimal attack to clear plastic cases - especially polysulphone and polycarbonate. 

 

KEY FEATURES AND BENEFITS 

 

 

•  Low viscosity for potting of small device casings 



 

 

•  Sufficient surface tension for blob-top applications on ceramic sensors 



 

 

•  Minimum discoloration with prolonged heat aging up to 105



°

 



HANDLING INFORMATION 

 

Mix ratio, parts by weight:  

 

 

 



 

100 (APTEK 6110-A)/35 (APTEK 6110-B) 

 

Work life*, 25



°

C, 45% RH, 100 gms, hrs.   

 

 

>3 



*adversely affected by heat and humidity 

 

Index of refraction, mixed wet @ 25



°

 



 

 

1.54 



 

Handling Notes: 

 

1.  Visually inspect containers of Part A before use.  It is a very pure material may crystallize upon prolonged storage 



below 30-35

°

C.  If crystals are present, place the container into 60-70



°

C air circulating oven for 1 to 4 hours until 

material is clear liquid.  Allow to cool to 25-30

°

C before use.  DO NOT FORCE COOL as this may cause 



recrystallization. 

 

2.  Part B is moisture sensitive and will react with atmospheric moisture to form a white “crystal-like” solid, which will not 



melt when heated.  To avoid this phenomenon, reseal container immediately after use and, if possible, purge with dry 

nitrogen or argon before resealing. This purging step and immediate resealing will help to minimize the white “crystal-

like” formation. 

 

3.  For best results, transfer degassed A/B mixtures to syringes for dispensing.  Syringes may be frozen and stored for  



up to one month  at -40°C or below for future use. 

 

 



 

 

 



APTEK 6110-A/B 

 

 





MIXING 

 

Weigh 100 parts by weight of APTEK 6110 Part A into a clean, dry, glass, metal or plastic container and then add 35 

parts of APTEK 6110 Part B.  Machine mix at slow speed or hand stir with glass or metal stirrer until complete and 

thorough blending in achieved.  Care should be taken to avoid any source of moisture contamination or air entrapment 

during mix.  Mixture may be warmed to 30

°

C maximum to facilitate degassing and handling. 



Note:  For best results and void free castings vacuum mixture (25-30

°

C) at less than 15mm Hg for 1-2 minutes after 



break.  Stop vacuuming if when material starts to boil. 

 

CURE SCHEDULE* 

 

2 hrs @ 60



°

C + 2 hrs @ 125

°



 



*This schedule is conservative, however, the user should determine the proper cure schedule for individual application 

requirements. 



TYPICAL PROPERTIES 

(values not to be used for specification purposes) 

 

CHARACTERISTICS 

 

APTEK 6110-A   

 

APTEK 6110-B   

TEST METHOD 

 

Clarity   

 

 

Clear to hazy/crystallized  



Clear to hazy 

 

Visual 



 

Color 


 

 

 



Pale yellow to pale blue   

Pale yellow/amber 

Visual 

to pale green/gray 



 

Specific gravity   

 

1.15 


 

 

 



0.94 

 

 



ASTM D-1475 

 

Viscosity @ 25



°

C, cps 


 

3400 (#3/10) 

 

 

65 (#2/100) 



 

ASTM D-1824 

spindle/speed, rpm 

 

Flash point, 



°

C   


 

>200 


 

 

 



>100 

 

 



ASTM D-92 

 

Shelf life @ 25



°

C, months 

factory sealed containers  

12 


 

 

 



12 

 

 



CURED PHYSICAL PROPERTIES 

 

 

APTEK 6110-A/B 

 

TEST METHOD 

 

Hardness, durometer D   



 

 

 



 

82 


 

 

ASTM D-2240 



 

Glass transition temp., 

°



 



 

 

 



115 

 

 



PERKIN ELMER TMS-2 

 

Thermal coefficients of expansion, in/in/



°

 



alpha 1   

 

 



 

 

 



74 

 

 



PERKIN ELMER TMS-2 

 

alpha 2   



 

 

 



 

            189 

 

 

PERKIN ELMER TMS-2 



 

CURED ELECTRICAL PROPERTIES 

 

 

APTEK 6110-A/B 

 

TEST METHOD 

 

Volume resistivity 



@25

°

C, ohm-cm 



 

 

 



 

      >1 x 10

15

 

 



 

ASTM D-257 

 

 

 

 

 

 



 

 

 



APTEK 6110-A/B 

 

 



 

 



 

SAFETY AND FIRST AID 

 

APTEK 6110-A is safe to handle when used properly.  Contact with skin or eyes can cause irritation and possible 

allergic skin reaction with prolonged or repeated use.  Avoid contact with skin and eyes and use in a well-ventilated 

area and avoid breathing vapors.  Incase of eye contact, flush with fresh clean water for at least 15 minutes; for skin 

contact, wash thoroughly with soap and water.  If swallowed, drink at least one pint of water and call a physician.  Refer 

to Material Safety Data Sheet for more details. 

 

APTEK 6110-B is safe to handle when used properly. It may cause eye irritation, possible eye damage, skin irritation 



and possible allergic skin reaction with direct contact.  Prolonged inhalation of vapors may result in breathlessness, 

coughing, and irritation of mucous membranes.  Avoid skin and eye contact and use in a well-ventilated area.  In case 

of eye contact, flush profusely with fresh clean water for 15 minutes and contact a physician.  For skin contact, wash 

thoroughly with soap and water.  If inhaled, move subject to fresh air and provide fresh water to drink.  If swallowed, 

dilute with at least one pint of water and contact physician immediately.  Refer to Material Safety Data Sheet for more 

details. 



FOR INDUSTRIAL USE ONLY 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



Issued: 4/1/03 

Revised: 11/29/16 - mjv 



APTEK

®

 is a registered trademark of Aptek Laboratories, Inc. 



Document Outline


Yüklə 34,51 Kb.

Dostları ilə paylaş:




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©azkurs.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin