Chapter 7-Pumps

Pump

Positive Displacement

Reciprocating

1.Piston

2.Plunger

Rotary

1.Gear

2.Screw

3.Vane

Dynamic

Centrifugal

1.Radial

2.Axial

3.Mixed 


 

 

CHAPTER 6 



 

VELOCIS SOLUTIONS @2018 

 

                         2 



 

Figure 7.1 indicates the chart used to define type of pump for particular head and flow. 

 

                 



 

 

                                                   Figure 7.1: Pump selection guide 



 

There  are  two  calculations  made  for  all  types  of  pumps:  net  positive  suction  head(NPSH)  and 

specific speed. 

 

 NPSH  

NPSH is an essential factor to be considered for proper pumping performance. The pressure at the 

inlet to a pump must be high enough to prevent cavitation occurring in the pump. Cavitation occurs 

when bubbles of vapour, or gas, form in the pump casing. Vapour bubbles will form if the pressure 

falls below the vapour pressure of the liquid. 

The net positive suction head available (NPSH

avail

) is the pressure at the pump suction, above the 

vapour pressure of the liquid, expressed as head of liquid. 

Pump manufacturers test their pumps for cavitation in a pump test facility by varying the volume 

flow rate and inlet pressure in a controlled manner. Specifically, at a given flow rate and liquid 

temperature, the pressure at the pump inlet is slowly lowered until cavitation occurs somewhere 

inside the pump. The value of NPSH is calculated and recorded at this operating condition. The 

process  is  repeated  at  several  other  flow  rates,  and  the  pump  manufacturer  then  publishes  a 

performance parameter called the required net positive suction head (NPSH

requir


), defined as the 

minimum NPSH necessary to avoid cavitation in the pump. The measured value of NPSH

requir

 varies 


with volume flow rate, and therefore NPSH

requir


 is often plotted on the same pump performance 


 

 


Yüklə 1,66 Mb.