2.6. Blood pressure sensor
If blood circulation is to be maintained in the body, tissues are to be perfused with oxygen.
Then correct pressure measurement has to be applied in the vascular system. The usual blood
pressure methods have: liquid coupling direct measurement, pipe-end sensing measurement,
indirect blood pressure sensing measurement. Liquid coupling direct measurement means
that the pipe filled with liquid is inserted into the measured part and that the pressure is
measured by liquid coupling of pipe end position in the body, which is the simplest method.
Pipe-end sensing measurement employs pipe-end sensor to measure blood pressure. Pipe-end
sensor which can convert the pressure signal into electronic signal is placed on the measured
part. And then the electronic signal measured is transmitted to the external wire. Such method
could avoid the distortion of signal of blood pressure. Pipe-end sensing measurement has a
lot of advantages, but such method needs to activate the skin and relative sensors have to been
placed into the body. Hence indirect blood pressure measurement is noted by people and
continuously explored. Blood-pressure meter is a classic example of indirect blood pressure
measurement, which is shown in figure 10.
In figure 10, the sensing principle is based on Coriolis sound. Gas is filled into cuff to hold back
the arterial blood flow. And then gas in cuff is sent out slowly to monitor whether there appears
arterial blood flow at the downstream of arterial blocking point. Here, the employed sensor is
common mercury pressure meter. And such method is up to the actual experience of staff.
Advances in Bioengineering
192


When coriolis sound is heard, namely when blood flows through artery blood pipe, blood
pressure in cuff is shrinking pressure in artery pipe. When blood flows recover normal level,
blood pressure in cuff is diastolic pressure of artery. Systole pressure and diastolic pressure
are recorded as blood pressure. Such method is not harmful to the skin or organ in the body.