A Pelletron charging system
creates a potential difference, resulting in the
negative ions being accelerated toward the terminal where they reach an energy
of ~3 MeV.
At the terminal, a gas stripping system removes the electrons from
the ions.
A second Pelletron chain then creates a potential difference between the terminal
and exit end, resulting in the now positive ions (protons) being further accelerated
to reach ~6 MeV before being extracted from the tank. Bending and steering
magnets then direct the extracted beam towards the nuclear microprobe. A
photograph of the line leading to the microprobe is shown in Figure 4-8.
Figure 4-8: Photograph of proton beam line leading to the nuclear microprobe chamber.
For the irradiations, plastic scintillator samples were mounted on a hexagonal
carousal sample holder and housed within the nuclear microprobe chamber under
vacuum conditions. The proton beam was passed
through an object slit and
collimator slit and a set of magnetic quadrupole triplets were used to focus the
beam onto a sample with a spot size of ~20-30 μm.
30
The beam was scanned in the x and y plane using a
raster pattern to achieve a
uniformly irradiated area of approximately 1.8 mm by 1.8 mm. This irradiation
technique was required because using a large diameter beam whic h is not scanned
over the sample resulted in an inhomogeneous intensity distribution of a Gaussian
shape which was not conducive to the required damage analysis techniques.
The beam current was determined by measuring the current generated across a
metal plate situated on the side opposite to the sample on the carousal . The beam
current, integrated per second, was recorded for the duration of each irradiation.
Two samples of each plastic scintillator type were irradiated per dose for targeted
doses of 0.8 MGy, 8 MGy, 25 MGy and 80 MGy.