40
The relative transmission is computed by taking
the ratio between the
transmissions in irradiated to un-irradiated samples. The spectra are multiplied
by a correction factor computed as the ratio of the
spectra of a control sample
taken on the two respective days of testing. The development of an absorptive
tint shifting to higher wavelengths as dose exposure
is increased can be more
clearly observed in these plots.
To compare the effect of transmission loss as a function of dose wi thin the various
samples, the loss at a wavelength of 430 nm is considered. This corresponds to
the peak absorption wavelength of the fiber; Kuraray Y -11(200) [28]; that these
scintillators are coupled to within the Tile Calorimeter
and would give an
indication into the performance of the scintillators as part of the coupled system.
The relative transmission at 430 nm for the various samples 4
weeks after
irradiation are shown in Figure 5-4 below.
Figure 5-4: Relative transmission at 430 nm for the various sample types measured 4
weeks after irradiation.
Transmission loss at 430 nm
Dose (Gy)
1e+6
1e+7
1e+8
Re
lati
ve
Trans
missio
n
(
a.u)
0,0
0,2
0,4
0,6
0,8
1,0
1,2
EJ200
EJ208
EJ260
Dostları ilə paylaş: