Reference Specifications for Civil Engineering Work 2001


Relative to a 3 m straightedge*



Yüklə 138,39 Kb.
səhifə11/22
tarix26.12.2016
ölçüsü138,39 Kb.
#3344
1   ...   7   8   9   10   11   12   13   14   ...   22
Relative to a 3 m straightedge*

Sub base

+ 10 mm - 30 mm

10 mm

Base

 10 mm

5 mm

* Limits to incorporate due allowance for design shape where relevant

Crossfall

Measurement: Measure crossfall at sub base and base transversely to the centreline. Ensure that the two selected points are more than 2 m apart.

Requirement: Do not depart from the corresponding design crossfall by more than 0.2% absolute. Maintain positive drainage slope towards pavement drainage system.

Other ground surfaces

Absolute level tolerance: ± 50 mm, provided the area matches adjacent construction.

Horizontal surfaces

Absolute tolerance: ± 50 mm, except where alignment with an existing road structure is necessary. Join new construction to the existing work in a smooth manner.