Figure 5.1 – Load bearing block positioning
-
Load classification:
In accordance with Table 5.1.
-
Loading condition
|
Class D (heavy duty)
|
Application
|
All road hierarchy classification
|
Nominal wheel load (kg)
|
8000
|
Serviceability design load (kN)
|
140
|
Ultimate limit state design load (kN)
|
210
|
Table 5.1 – Load classification
Note: The load classification table is in accordance with AS 3996.
Test loads:
All kerb adaptors shall be designed to load class D (heavy duty) in accordance with Table 5.1 or Table 3.1 of AS 3996.
For circular openingi (CO) 250 mm, the test loads shall be the serviceability and ultimate design loads given in Table 5.1 or Table 3.1 of AS 3996 multiplied by the appropriate factor.
The Factor is the clear openingii area, in mm2, of the top surface divided by ().
Test loads are calculated to be:
Dostları ilə paylaş: |