Chapter 7-Pumps

CHAPTER 6 

 

VELOCIS SOLUTIONS @2018 

 

                         16 



may be noisy and unstable, which indicates that the fan may be oversized (larger than necessary). 

For  these  reasons,  it  is  usually  best  to  run  a  propeller  fan  at,  or  slightly  above,  its  maximum 

efficiency point. 

  

                   



                      

 

                                    Figure 7.13:  Performance curves of an axial pump 



 

POSİTİVE DİSPLACEMENT PUMP 

 

People have designed numerous positive-displacement pumps throughout the centuries. In each 



design, fluid is sucked into an expanding volume and then pushed along as that volume contracts, 

but the mechanism that causes this change in volume differs greatly among the various designs. 

Some designs are very simple, like the flexible-tube peristaltic pump that compresses a tube by 

small wheels, pushing the fluid along. (This mechanism is somewhat similar to peristalsis in your 

esophagus or intestines, where muscles rather than wheels compress the tube.) Others are more 

complex,  using  rotating  cams  with  synchronized  lobes,  interlocking  gears,  or  screws.  Positive-

displacement pumps are ideal for high-pressure applications like pumping viscous liquids or thick 

slurries, and for applications where precise amounts of liquid are to be dispensed or metered, as 

in medical applications. 