Fig. 10. The form of the magnetic field vectors in the section of
the generator.
Fig. 11. The distribution of the magnetic field density in the
cross section of the generator.
On Figure 10, an experimental user can easily see
how the field lines of the permanent magnet are oriented
in the axial generator. This creates great convenience for
the user, because in real life the magnetic field is an
invisible phenomenon. In figure 11 shows the leakage
density of the magnetic field in the generator shell. Here,
the surfaces marked in red have the lowest magnetic
field strength, and the surfaces marked in blue have the
lowest magnetic field strength. The energy density
generated in the generator sheath is shown in fig. 12. The
energy density is given by the color cross section too.
4
E3S Web of Conferences 288, 01057 (2021) https://doi.org/10.1051/e3sconf/202128801057
SUSE-2021
The color density match is located at the top left of the
image.
Dostları ilə paylaş: |