28
Figure 6 Experimental setup for the estimation of plastic scintillators light output.
Detailed analysis of spectra registered during gamma quanta interaction with plastic
scintillator and description of the phenomenon
itself are the subject of
Chapter 7.2: Spectral properties of J-PET scintillators. The first preliminary studies relied
on fitting Fermi function to the falling edge of the spectrum. That allows to estimate
roughly the relative light yield of tested scintillators. Fermi function is given by the
equation (1):
(1).
Parameters
denoted as P
0
, P
1
, P
2
, P
3
are related to maximal values of the function, the
middle of the edge, slope and
minimal values of the function, respectively.
The function was fitted to spectra as it is shown in Fig. 7 registered for stilbene
which was taken as standard. In the spectrum, histogram of signals amplitudes is presented.
Amplitudes are proportional to the number of photons produced by scintillator during
interaction with gamma quanta. The absolute number of photons produced by scintillator
interacting with gamma quanta was not calculated. The aim of
this test was to check if
developed materials have a potential for being used as scintillators.
29
P
1
parameter describing the middle of the falling edge, was a measure of
scintillators light output. P
1
determined for obtained scintillators
were compared to the
parameter value of stilbene. Results of such rough estimation of scintillators light output
are presented in Tab. 7.