intelliflo3-pro3-vsf-install-guide

TO PREVENT FREEZE DAMAGE:
1. 
Press ON/STOP to stop the pump and disconnect 
all power to the pump at the circuit breaker.
2. 
Open the filter's air relief valve and relieve all 
pressure from the filtration system.
3. Remove both drain plugs from the bottom of the 
strainer pot and drain the pump. Store the plugs in 
the strainer basket.
4. Cover the motor to protect it from severe rain, snow 
and ice.
Note:
Do not wrap motor with plastic or other air 
tight materials during winter storage. Never cover 
the motor when operating or expecting operation.
THIS SYSTEM OPERATES UNDER HIGH PRESSURE
. When 
any part of the circulating system is serviced, air can enter the 
system and become pressurized. Pressurized air can cause the 
lid to separate which can result in serious injury, death, or property 
damage. To avoid this potential hazard, follow above instructions.
Always disconnect power to the pump at the circuit breaker and relieve pressure in the filtration system before servicing the pump. Failure 
to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. Do NOT attempt to adjust or 
service without consulting your dealer or a qualified pool technician. Read the entire Installation and Maintenance Guide before attempting to use, service, or 
adjust the pool filtering system or heater.
Do NOT open the pump strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated 
in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause 
serious personal injury. In order to avoid the possibility of personal injury, ensure the suction and return valves are open and strainer pot temperature is cool 
to touch, then open with extreme caution.
To prevent damage to the pump and for proper operation of the system, clean pump strainer and skimmer baskets regularly.