PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Pump is Noisy or
Operating Loudly.
Debris in contact with cooling fan
Ensure the fan guard is clean. Use compressed air to
remove any dirt, debris or blockages.
Clogged impeller
Disassemble the pump
and remove debris from the
impeller.
Refer to
Disassembly
on page 16 and
Reassembly
on page 16 for instructions.
Too much debris in strainer basket
causing cavitation
Clean the pump strainer basket.
Refer to
Cleaning the Pump Strainer Basket on page
14
for instructions.
Motor speed too high
Consider reducing the speed if possible.
Pump is Leaking
(from Strainer Pot -
Seal Plate Joint)
1. Ensure the seal plate O-ring is not pinched between
the seal plate and strainer pot.
2. Tighten the bolts joining the strainer pot and the
seal plate.
3.
If leak persists, disassemble the pump.
Inspect all O-rings and seals for damage or debris
build-up. Replace or clean the seals if necessary.
Refer to
Disassembly
on page 16 and
Reassembly
on page 16 for instructions.
Dostları ilə paylaş: