74
Scintillators containing smaller amounts of the WLS exhibit lower light output because
inefficient
energy transfer, while for those with higher than 0.05 ‰ WLS concentration,
the concentration quenching occurs. Such light output dependence on the WLS
concentration was observed also in case of commercial wavelength shifter POPOP.
Light signals in the 0.05J-PET scintillator were analyzed as well. Rise and decay
times of the signals were determined to be equal to 0.50 ns and 1.91 ns, respectively. Rise
time of pulses appearing in the J-PET scintillator is equal to the rise time of signals in
BC-420 scintillator, however decay time is longer by about 0.4 ns. BC-420 is one of the
best scintillators by Saint Gobain considering time properties.
When comparing J-PET to
other scintillators produced by the company, its decay time has the typical value.
Since small molecular weight of scintillators polymeric matrix decreases its light
output, it was essential to determine molecular weight of J-PET scintillator. It was
established that molecular weight of J-PET scintillator, exceeding 10
5
u, has sufficiently
high value for which the light output value is not being affected anymore. Considering
polymer influence on a scintillator as
a system, light output is maximal.
Structure of J-PET scintillator was studied using two methods: Positron
Annihilation Lifetime Spectroscopy (PALS) and Differential Scanning Calorimetry (DSC).
Glass transition temperature (T
g
), temperature in which structural transition occur (T
γ
)
and softening point which is taken as a maximal temperature at which scintillator can act
was determined. In order to discuss the influence of scintillating dopants on the structure,
results obtained for J-PET scintillator and pure polymeric matrix samples were compared.
Significant discrepancy between temperatures determined by PALS and DSC were
observed. The differences are related to the chosen experimental techniques and their
limitations.
As construction of the J-PET/MR hybrid tomograph requires hundredths of at least
50 cm long plastic scintillators, the next step of conducted research was setting the
conditions for larger than studied so far scintillating samples production.
Design and
preparation of the special reactor was necessary. Many difficulties were connected with the
choice of proper material for the form. The furnace for polymerization has been changed
because the geometry of the previous one prevented the preparation of large scintillator
strips. Apart from purely geometrical issues regarding the form and furnace construction
one has to take into account the fact that the chemical composition, especially wavelength
75
shifter concentration in scintillating material is not a fixed value in terms of size and shape
of synthesized sample [31]. Therefore, optimization of the WLS concentration has to be
performed each time the geometry of the scintillator is to be changed.
One of the factors, which should be determined for long J-PET scintillator strips, is
attenuation length. As the novel J-PET scintillator has different spectral
characteristics of
emitted scintillation light, that is shifted towards longer wavelengths than for commercial
products, also the setup for the wavelength dependent light attenuation measurement
should be modified. So far used vacuum photomultipliers are less sensitive for the longer
wavelengths, whereas silicon photomultipliers quantum efficiency reaches maximum in
that region. Therefore, a next step for better attenuation length determination for J-PET
scintillator will be silicon photomultipliers use in the experimental system.
Properties of J-PET scintillator,
like light output, rise and decay time, emission
spectrum and H:C ratio were compared to properties of commercially available
scintillators produced by Saint Gobain in Tab. 12. No significant difference in any of the
value was observed. This indicates that properties of J-PET scintillator are similar to
properties of commercial plastic scintillators. Emission spectrum,
which is specific for
particular scintillator, is important in the view of scintillator application, because it has to
be matched to the particular scintillation light detector which is used in the experiment.
H:C ratio is typical for plastic scintillators.