PLC Program
Here is PLC program to
Jump to Other Process, along with program explanation and run time test cases.
List
of Inputs and Outputs
I:1/0
= Input to Jump to Label (Input)
I:1/1
=
Input A
(Input)
I:1/2
=
Input B
(Input)
I:1/3
=
Input C
(Input)
I:1/4
=
Sensor Input
(Input)
O:2/0
= Output 0
(Output)
O:2/1
= Output 1
(Output)
O:2/2
= Output 2
(Output)
O:2/3
= Output 3
(Output)
Q2:0
= Jump (JMP and LBL)
(I/O)
Ladder
Diagram
to
perform
Jumping
Program Description
RUNG000 comprises of a Manual input which may be a toggle button or sensor output by which operation is
performed.
Until I:1/0 is pressed, JMP does not energize, that means program is being scanned rung by rung and it
does not affect program or process at all.
When I:1/0 is pressed, program is directly jumped to the LBL and scans RUNG004.
If Sensor Input I:1/4 is true, it energizes O:2/3 turning ON Output 3.
As long as JMP is energized, all the output between JMP and LBL rungs are skipped and Input I:1/1 to I:1/3
do not affect O:2/0 to O:2/2 at all.
Important thing to note here is that if Latch Output is used between JMP-LBL rungs and is active then it is
not unlatched when JMP energizes.