Installation Guide: IntelliFlo3 and IntelliPro3 vsf pool Pump


Always disconnect power to the pump at the circuit breaker before servicing the pump. Failure to do so could result in death



Yüklə 6,98 Mb.
Pdf görüntüsü
səhifə13/37
tarix16.12.2023
ölçüsü6,98 Mb.
#182724
1   ...   9   10   11   12   13   14   15   16   ...   37
intelliflo3-pro3-vsf-install-guide

Always disconnect power to the pump at the circuit breaker before servicing the pump. Failure to do so could result in death 
or serious injury to service people, users or others due to electric shock. 
Read all servicing instructions before working on the pump.
Note:
 
ALWAYS reinstall the wiring cover onto the field wiring compartment when leaving the pump unsupervised. This 
will prevent foreign matter (i.e. water, dust, etc.) from accumulating in the drive.
Note:
 
When connecting the pump to an automation system, continuous power must be supplied to the pump by 
connecting it directly to the circuit breaker. When using an automation system, be sure that no other lights or 
appliances are on the same circuit.
Grounding
1. Permanently ground the drive using the green 
Ground Wire Screw and ensure the ground wire 
is connected to an electrical service ground.
Bonding
1. Bond the motor to the structure in accordance 
with the National Electrical Code. 
2. Use a solid copper bonding conductor not 
smaller than 8 AWG. For Canadian installations, 
a 6 AWG or larger solid copper bonding 
conductor is required. 
3. Run a wire from the bonding lug, found on the 
side of the motor, to the bonding structure.
Connect the wire to all metal parts of the pool
electrical equipment, metal conduit, and metal 
piping within 5 ft. (1.5 m) of the inside walls of 
the pool.
GROUND SCREW 
(GREEN)
MAIN POWER 
TERMINAL 
BONDING 
LUG
DRIVE WIRING COMPARTMENT


4
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation and Maintenance Guide
Connecting to an Automation System
All IntelliFlo3 VSF and IntelliPro3 VSF pumps are compatible with Pentair automation systems. Refer to the 
automation system manual for further details on connecting your pump to a specific automation system.
When connecting to a Pentair Automation System, connect 18 to 24 AWG, two-conductor cable to DATA+ and DATA- 
terminals only. If needed, 12V and Ground terminals are also provided.

Yüklə 6,98 Mb.

Dostları ilə paylaş:
1   ...   9   10   11   12   13   14   15   16   ...   37




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©azkurs.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin