intelliflo3-pro3-vsf-install-guide

Max Amps
Input (Hz)
1.5 HP
115/208-230
12/6.4-5.9
50/60
3 HP
208-230
12.4-11.2
50/60
Circuit Protection:
Require GFCI protection device, in 
accordance with all national and local electrical codes. The 
drive will operate on 2-Phase Line-Line-Ground, as well as 
Line-Neutral-Ground electrical systems.
Wiring
1. Ensure all appropriate electrical breakers and 
switches are turned off before wiring the motor.
STORED CHARGE
- Wait at least sixty (60) 
seconds before servicing.
2. Ensure the supply voltage meets the requirements listed 
on the motor nameplate. If these requirements are not 
met, permanent motor damage may occur.
3. The pump should be permanently connected to its own 
independent GFCI-protected circuit.
 
Note:
Pentair offers 2-Pole 20 Amp GFCI breakers 
(P/N PA220GF) which offer personnel protection 
while meeting 2008 to current NEC Standards for 
Pool Pumps.
 Note:
If using a two-pole relay or timer, apply and 
remove power to both POWER LINE TERMINALS.
4. For wiring sizes and general electrical guidelines
please follow the specifications defined in the National 
Electric Code and any local codes as required.
5. Use strain reliefs and ensure all electrical connections 
are clean and tight.
Note:
Any unused conduit openings should be sealed 
with the provided conduit plugs.
6. Cut all wires and conductors to appropriate lengths to 
help prevent conductors from arcing or overlapping once 
connected.
Electrical Installation
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.
This pump must be installed by a licensed or certified electrician or a qualified 
service professional in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation 
will create an electrical hazard which could result in death or serious injury to users, installers, or others due to electrical shock, and may 
also cause damage to property.