intelliflo3-pro3-vsf-install-guide

STRAINER POT LID
Before starting the pump, ALWAYS follow the instructions below. Failure to follow these instructions could result 
in property damage and/or personal injury.
1. Open the filter's air relief valve. 
2. Open all suction and return line valves. 
3. Ensure pool return line is completely open and clear of any blockages. 
4. Ensure the strainer pot is filled with water.
5. Stand clear of the filter or other pressurized vessels.
Never allow the pump to run without both halves of the motor shroud installed. Operating the pump without motor shrouds 
installed may cause the drive to overheat and damage the drive.


7
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation and Maintenance Guide
Priming the Pump
 (continued)
10. Press ON/STOP
 
to start the pump. 
The pump will begin to prime (if enabled) and ramp up to the programmed priming speed.
11. When a steady stream of water appears from the air relief valve, close the valve.
12. Do not allow your pump to run longer than 30 minutes without successfully priming. 
If the pump does not prime, check your priming settings or refer to 
TROUBLESHOOTING, page 19
.
Default Settings
If the pump is started using the ON/STOP button before a customized schedule is programmed, the pump will run 
the default Program 1 schedule (24 hours at 30 GPM). The Quick Clean button can be used to temporarily override 
this default Program 1 schedule. Default programs can be edited via the Pentair Home app or the using the optional 
touchsreen.
Restore System Defaults
Restoring system defaults will delete all custom programs and restore all default settings and programs. Network 
settings and the security PIN (if enabled) will be retained. This can be done via the Pentair Home App, drive controls, or 
optional touchscreen controller.
To restore system defaults using drive controls, disable the pump then press and hold both the CONNECT and QUICK 
CLEAN buttons for 3 seconds.
Factory Reset
A factory reset erases all user-entered information, including custom programs, security PIN, and network settings. All 
programs will be restored to factory defaults. A factory reset can only be performed using the drive controls. 
To perform a factory reset, disable the pump then press and hold all three buttons for 3 seconds.