Ladder Logic (lad) for S7-300 and S7-400 Programming


  BR ---|   |---  Exception Bit Binary Result



Yüklə 1,39 Mb.
Pdf görüntüsü
səhifə12/16
tarix05.05.2020
ölçüsü1,39 Mb.
#31077
1   ...   8   9   10   11   12   13   14   15   16
STEP 7 - Ladder Logic for S7-300 and S7-400


12.5 
BR ---|   |---  Exception Bit Binary Result 
Symbol 
or negation
/
BR
BR
 
 
Description  
BR ---|   |--- (Exception Bit BR Memory) or BR ---| / |---  (Negated Exception Bit BR Memory) 
contact symbols are used to test the logic state of the BR bit in the status word. Used in series, the 
result of the scan is linked to the RLO by AND, used in parallel, it is linked to the RLO by OR. The 
BR bit is used in the transition from word to bit processing. 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Example 
I 0.0
BR
I 0.2
S
Q 4.0
 
 
Q4.0 is set if I0.0 is "1" or I0.2 is "0" and in addition to this RLO the logic state of the BR bit is "1". 
 

 
Status Bit Instructions
 
 
12.6 ==0 ---|   |---  Result Bit Equal 0
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
Reference Manual, 04/2017, A5E41524738-AA 
147 
12.6 
==0 ---|   |---  Result Bit Equal 0 
Symbol 
or negation
/
==0
==0
 
 
Description  
==0 ---|   |--- (Result Bit Equal 0) or ==0 ---| / |--- (Negated Result Bit Equal 0) contact symbols are 
used to recognize if the result of a math function is equal to "0". The instructions scan the condition 
code bits CC  1 and CC  0 in the status word in order to determine the relation of the result to "0". 
Used in series, the result of the scan is linked to the RLO by AND, used in parallel, it is linked to the 
RLO by OR. 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Examples 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
==0
S
Q 4.0
 
 
The box is activated by signal state "1" at I0.0. If the value of IW0 is equal to the value of IW2, the 
result of the math function "IW0 - IW2" is "0". Q4.0 is set if the function is properly executed and the 
result is 
equal to "0". 
 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
==0
S
Q 4.0
 
 
Q4.0 is set if the function is properly executed and the result is 
not equal to "0". 
 

Status Bit Instructions
 
12.7 <>0 ---|   |---  Result Bit Not Equal 0
 
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
148 
Reference Manual, 04/2017, A5E41524738-AA 
12.7 
<>0 ---|   |---  Result Bit Not Equal 0 
Symbol 
or negation
/
<>0
<>0
 
 
Description  
<>0 ---|   |--- (Result Bit Not Equal 0) or <>0 ---| / |--- (Negated Result Bit Not Equal 0) contact 
symbols are used to recognize if the result of a math function is not equal to "0". The instructions 
scan the condition code bits CC  1 and CC  0 in the status word in order to determine the relation of 
the result to "0". Used in series, the result of the scan is linked to the RLO by AND, used in parallel, 
it is linked to the RLO by OR. 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Examples 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
<>0
S
Q 4.0
 
 
The box is activated by signal state "1" at I0.0. If the value of IW0 is different to the value of IW2, 
the result of the math function "IW0 - IW2" is not equal to "0". Q4.0 is set if the function is properly 
executed and the result is 
not equal to "0". 
 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
<>0
S
Q 4.0
 
 
Q4.0 is set if the function is properly executed and the result is 
equal to "0". 
 

 
Status Bit Instructions
 
 
12.8 >0 ---|   |---  Result Bit Greater Than 0
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
Reference Manual, 04/2017, A5E41524738-AA 
149 
12.8 
>0 ---|   |---  Result Bit Greater Than 0 
Symbol 
or negation
/
>0
>0
 
Description 
>0 ---|   |--- (Result Bit Greater Than 0) or >0 ---| / |--- (Negated Result Bit Greater Than Zero) 
contact symbols are used to recognize if the result of a math function is greater than "0". The 
instructions scan the condition code bits CC  1 and CC  0 in the status word in order to determine 
the relation to "0". Used in series, the result of the scan is linked to the RLO by AND, used in 
parallel, it is linked to the RLO by OR. 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Example 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
>0
S
Q 4.0
 
 
The box is activated by signal state "1" at I0.0. If the value of IW0 is higher than the value of IW2, 
the result of the math function "IW0 - IW2" is greater than "0". Q4.0 is set if the function is properly 
executed and the result is 
greater than "0". 
 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
>0
S
Q 4.0
 
 
Q4.0 is set if the function is properly executed and the result is 
not greater than "0". 
 

Status Bit Instructions
 
12.9 <0 ---|   |---  Result Bit Less Than 0
 
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
150 
Reference Manual, 04/2017, A5E41524738-AA 
12.9 
<0 ---|   |---  Result Bit Less Than 0 
Symbol 
or negation
/
<0
<0
 
 
Description 
<0 ---|   |--- (Result Bit Less Than 0) or <0 ---| / |--- (Negated Result Bit Less Than 0) contact 
symbols are used to recognize if the result of a math function is less than "0". The instructions scan 
the condition code bits CC  1 and CC  0 in the status word in order to determine the relation of the 
result to "0". Used in series, the result of the scan is linked to the RLO by AND, used in parallel, it is 
linked to the RLO by OR. 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Example 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
<0
S
Q 4.0
 
 
The box is activated by signal state "1" at I0.0. If the value of IW0 is lower than the value of IW2, 
the result of the math function "IW0 - IW2" is less than "0". Q4.0 is set if the function is properly 
executed and the result is 
less than "0". 
 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
<0
S
Q 4.0
 
 
Q4.0 is set if the function is properly executed and the result is 
not less than "0". 
 

 
Status Bit Instructions
 
 
12.10 >=0 ---|   |---  Result Bit Greater Equal 0
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
Reference Manual, 04/2017, A5E41524738-AA 
151 
12.10  >=0 ---|   |---  Result Bit Greater Equal 0 
Symbol 
or negation
/
>=0
>=0
 
Description 
>=0 ---|   |--- (Result Bit Greater Equal 0) or >=0 ---| / |--- (Negated Result Bit Greater Equal 0) 
contact symbols are used to recognize if the result of a math function is greater than or equal to 
"0". The instructions scan the condition code bits CC  1 and CC  0 in the status word in order to 
determine the relation to "0". Used in series, the result of the scan is linked to the RLO by AND, 
used in parallel, it is linked to the RLO by OR. 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Example 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
>=0
S
Q 4.0
 
 
The box is activated by signal state "1" at I0.0. If the value of IW0 is higher or equal to the value of 
IW2, the result of the math function "IW0 - IW2" is greater than or equal to "0". Q4.0 is set if the 
function is properly executed and the result is 
greater than or equal to "0". 
 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
>=0
S
Q 4.0
 
 
Q4.0 is set if the function is properly executed and the result is 
not greater than or equal to "0". 
 

Status Bit Instructions
 
12.11 <=0 ---|   |---  Result Bit Less Equal 0
 
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
152 
Reference Manual, 04/2017, A5E41524738-AA 
12.11  <=0 ---|   |---  Result Bit Less Equal 0 
Symbol 
or negation
/
<=0
<=0
 
 
Description  
<=0 ---|   |--- (Result Bit Less Equal 0) or <=0 ---| / |--- (Negated Result Bit Less Equal 0) contact 
symbols are used to recognize if the result of a math function is less than or equal to "0". The 
instructions scan the condition code bits CC  1 and CC  0 in the status word in order to determine 
the relation of the result to "0". Used in series, the result of the scan is linked to the RLO by AND, 
used in parallel, it is linked to the RLO by OR. 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Examples 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
<=0
S
Q 4.0
 
 
The box is activated by signal state "1" at I0.0. If the value of IW0 is less than or equal to the value 
of IW2 the result of the math function "IW0 - IW2" is less than or equal to "0". Q4.0 is set if the 
function is well properly executed and the result is 
less than or equal to "0". 
 
SUB_I
EN
OUT
IN2
ENO
IN1
IW2
IW0
MW10
I 0.0
<=0
S
Q 4.0
 
 
Q4.0 is set if the function is properly executed and the result is 
not less than or equal to "0". 
 

 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
Reference Manual, 04/2017, A5E41524738-AA 
153 
13 
Timer Instructions 
13.1 
Overview of Timer Instructions 
Description  
-  You can find information for setting and selecting the correct time under  "Location of a 
Timer in Memory and Components of a Timer". 
The following timer instructions are available: 

  S_PULSE     Pulse S5 Timer 

  S_PEXT       Extended Pulse S5 Timer 

  S_ODT         On-Delay S5 Timer 

  S_ODTS       Retentive On-Delay S5 Timer 

  S_OFFDT      Off-Delay S5 Timer 

  ---( SP )         Pulse Timer Coil 

  ---( SE )         Extended Pulse Timer Coil 

  ---( SD )         On-Delay Timer Coil 

  ---( SS )         Retentive On-Delay Timer Coil 

  ---( SA )         Off-Delay Timer Coil 

Timer Instructions
 
13.2 Location of a Timer in Memory and Components of a Timer
 
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
154 
Reference Manual, 04/2017, A5E41524738-AA 
13.2 
Location of a Timer in Memory and Components of a Timer 
Area in Memory 
Timers have an area reserved for them in the memory of your CPU. This memory area reserves 
one 16-bit word for each timer address. The ladderlogic instruction set supports 256 timers. Please 
refer to your CPU’s technical information to establish the number of timer words available. 
The following functions have access to the timer memory area: 

  Timer instructions 

  Updating of timer words by means of clock timing. This function of your CPU in the RUN mode 
decrements a given time value by one unit at the interval designated by the time base until the 
time value is equal to zero. 
Time Value 
Bits 0 through 9 of the timer word contain the time value in binary code. The time value specifies a 
number of units. Time updating decrements the time value by one unit at an interval designated by 
the time base. Decrementing continues until the time value is equal to zero. You can load a time 
value into the low word of accumulator 1 in binary, hexadecimal, or binary coded decimal (BCD) 
format.  
You can pre-load a time value using either of the following formats: 

  W#16#wxyz 
-  Where w = the time base (that is, the time interval or resolution) 
-  Where xyz = the time value in binary coded decimal format 

  S5T#a
H_bM_cS_dMS  
-  Where H = hours, M = minutes, S = seconds, and MS = milliseconds;  
a, b, c, d are defined by the user. 
-  The time base is selected automatically, and the value is rounded to the next lower number 
with that time base. 
The maximum time value that you can enter is 9,990 seconds, or 2H_46M_30S. 
S5TIME#4S = 4 seconds 
s5t#2h_15m = 2 hours and 15 minutes 
S5T#1H_12M_18S = 1 hour, 12 minutes, and 18 seconds 

 
Timer Instructions
 
 
13.2 Location of a Timer in Memory and Components of a Timer
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
Reference Manual, 04/2017, A5E41524738-AA 
155 
Time Base 
Bits 12 and 13 of the timer word contain the time base in binary code. The time base defines the 
interval at which the time value is decremented by one unit. The smallest time base is 10 ms; the 
largest is 10 s. 
 
Time Base 
Binary Code for the Time Base 
10 ms 
00 
100 ms 
01 
1 s 
10 
10 s 
11 
 
Values that exceed 2h46m30s are not accepted. A value whose resolution is too high for the range 
limits (for example, 2h10ms) is truncated down to a valid resolution. The general format for S5TIME 
has limits to range and resolution as shown below: 
 
Resolution 
Range 
0.01 second 
10MS to 9S_990MS 
0.1 second 
100MS to 1M_39S_900MS 
1 second 
1S to 16M_39S 
10 seconds 
10S to 2H_46M_30S 
Bit Configuration in the Time Cell 
When a timer is started, the contents of the timer cell are used as the time value. Bits 0 through 11 
of the timer cell hold the time value in binary coded decimal format (BCD format: each set of four 
bits contains the binary code for one decimal value). Bits 12 and 13 hold the time base in binary 
code.  
The following figure shows the contents of the timer cell loaded with timer value 127 and a time 
base of 1 second: 
x x 1 0
15...
...8 7...
...0
0 0 0 1 0 0 1 0 0 1 1 1
1
2
7
Time value in BCD (0 to 999)
Time base
1 second
Irrelevant: These bits are ignored when the timer is started.
 
 

Timer Instructions
 
13.2 Location of a Timer in Memory and Components of a Timer
 
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
156 
Reference Manual, 04/2017, A5E41524738-AA 
Reading the Time and the Time Base 
Each timer box provides two outputs, BI and BCD, for which you can indicate a word location. The 
BI output provides the time value in binary format. The BCD output provides the time base and the 
time value in binary coded decimal (BCD) format. 
Choosing the right Timer 
This overview is intended to help you choose the right timer for your timing job.  
t
t
t
t
t
I 0.0
Q 4.0   S_PULSE
Q 4.0   S_PEXT
Q 4.0   S_ODT
Q 4.0   S_ODTS
Q 4.0   S_OFFDT
 
 
Timer 
Description 
S_PULSE 
Pulse timer  
The maximum time that the output signal remains at 1 is the same as the 
programmed time value t. The output signal stays at 1 for a shorter period if the 
input signal changes to 0. 
S_PEXT 
Extended pulse timer  
The output signal remains at 1 for the programmed length of time, regardless 
of how long the input signal stays at 1. 
S_ODT 
On-delay timer 
The output signal changes to 1 only when the programmed time has elapsed 
and the input signal is still 1. 
S_ODTS  
Retentive on-delay timer 
The output signal changes from 0 to 1 only when the programmed time has 
elapsed, regardless of how long the input signal stays at 1. 
S_OFFDT 
Off-delay timer 
The output signal changes to 1 when the input signal changes to 1 or while the 
timer is running. The time is started when the input signal changes from 1 to 0.  
 

 
Timer Instructions
 
 
13.3 S_PULSE  Pulse S5 Timer
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
Reference Manual, 04/2017, A5E41524738-AA 
157 
13.3 
S_PULSE  Pulse S5 Timer 
Symbol 
S_PULSE
BI
TV
R
BCD
S_IMPULS
DUAL
TW
S
Q
English
German
T no.
T-Nr.
S
Q
R
DEZ
 
 
Parameter 
English  
Parameter 
German  
Data Type 
Memory Area 
Description 
T no. 
T-Nr. 
TIMER 

Timer identification number; 
range depends on CPU 


BOOL 
I, Q, M, L, D 
Start input 
TV 
TW 
S5TIME   
I, Q, M, L, D 
Preset time value 


BOOL 
I, Q, M, L, D 
Reset input 
BI 
DUAL 
WORD 
I, Q, M, L, D 
Remaining time value, integer 
format 
BCD 
DEZ 
WORD 
I, Q, M, L, D 
Remaining time value, BCD 
format 


BOOL 
I, Q, M, L, D 
Status of the timer 
Description  
S_PULSE (Pulse S5 Timer) starts the specified timer if there is a positive edge at the start (S) 
input. A signal change is always necessary in order to enable a timer. The timer runs as long as the 
signal state at input S is "1", the longest period, however, is the time value specified by input TV. 
The signal state at output Q is "1" as long as the timer is running. If there is a change from "1" to 
"0" at the S input before the time interval has elapsed the timer will be stopped. In this case the 
signal state at output Q is "0". 
The timer is reset when the timer reset (R) input changes from "0" to "1" while the timer is running. 
The current time and the time base are also set to zero. Logic "1" at the timer's R input has no 
effect if the timer is not running. 
The current time value can be scanned at the outputs BI and BCD. The time value at BI is binary 
coded, at BCD it is BCD coded. The current time value is the initial TV value minus the time 
elapsed since the timer was started. 

Timer Instructions
 
13.3 S_PULSE  Pulse S5 Timer
 
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
158 
Reference Manual, 04/2017, A5E41524738-AA 
Timing Diagram 
Pulse timer characteristics: 
t
t
t
t = Programmed time
RLO at S input
RLO at R input
Timer running
Scan for "1"
Scan for "0"
 
 
Status word 
 
 
BR 
CC 1 
CC 0 
OV 
OS 
OR 
STA 
RLO 
/FC 
writes: 









Example 
S_PULSE
S
Q
BI
TV
R
BCD
I 0.0
I 0.1 S5TIME#2S
Q 4.0
T 5
 
 
If the signal state of input I0.0 changes from "0" to "1" (positive edge in RLO), the timer T5 will be 
started. The timer will continue to run for the specified time of two seconds (2  s) as long as I0.0 is 
"1". If the signal state of I0.0 changes from "1" to "0" before the timer has expired the timer will be 
stopped. If the signal state of input I0.1 changes from "0" to "1" while the timer is running, the time 
is reset. 
The output Q4.0 is logic "1" as long as the timer is running and "0" if the time has elapsed or was 
reset. 

 
Timer Instructions
 
 
13.4 S_PEXT  Extended Pulse S5 Timer
 
Ladder Logic (LAD) for S7-300 and S7-400 Programming 
Reference Manual, 04/2017, A5E41524738-AA 
159 
Yüklə 1,39 Mb.

Dostları ilə paylaş: