Methods of air sampling
3. Impingement
|
səhifə | 8/8 | tarix | 02.06.2023 | ölçüsü | 0,72 Mb. | | #123399 |
| Atmospheric-pollution
Methods of air sampling
3. Impingement 3. Impingement - To collect atmospheric particles in a liquid medium
- The air is sucked through a glass instrument at a defined rate into the fluid
- The microbial load: determined by examining the fluid
4. Precipitation - The precipitation of atmospheric particles in two ways:
1. Thermal precipitation - A slowly moving air current (3 lit/min) is directed between heated & cooled surfaces (distance 0.038 cm)
- The heated wire/surface repulses the particles towards cold surface
- They get collected in cold surface
- The organisms are then transferred on to the agar medium
2. Electrostatic precipitation - Collects the organisms on the basis of their electric charge
- It is a highly efficient instrument for collecting the airborne particles
Methods of air sampling
5. Filtration 5. Filtration - The microorganisms are trapped on a filter (cotton, glass wool or paper) or membrane filter
- Membrane filter technique is considered to be better for the purpose
- Air is filtered through the membrane
- The particles (with microbes) are impunged on this membrane
- The membrane is then placed on a paper saturated with an appropriate medium & incubated
6. Sieve (cascade) samplers - It is desired to collect samples of air on the basis of the particle size of the pollutant
- Sieves of varying sizes are arranged in a cascading manner (one upon the other)
- Larger particles are collected on top
- Smaller ones towards the bottom sieves
- Cascade impactor is a highly efficient trap
Methods of air sampling
- Minimize the production & release of pollutants near the animal or human dwellings
- Control of dust particles: by improving sanitary conditions within the houses
- Frequent washings of floor & equipment: controlling the dust within the buildings
- Vacuum cleaners: used effectively
- Proper ventilation: a prompt clearance of foul gases & particulate pollutants
Filters can be installed to check the entry of external contaminants - Use of laminar air flow systems for closed compartments/ cabins
Allows unidirectional passage of air through cellulose acetate filters