SOLAR PUMPING
Guidelines - Electrical design and installation of solar pumps
3
PROTECTION CABINET
The protection box is essential on all pumping sites where the operating voltage (at the pump) is higher than 120V. The
installation of a cabinet concerns almost all pump systems as this voltage is reached even on small installations (4 panels of
250Wp).
The protection cabinet is used to:
•
Protect equipment from overload (fuses)
•
Switch off the installation to perform maintenance via a main switch ON / OFF
•
Protect the installation from lightning strikes and surges (surge arresters - SPD)
•
Create
a central point of grounding
•
On some high power pumping systems, it also used to connect the different strings of solar panels together, and
accumulate their power in a single output that will power the controller or the inverter
FIGURE 4:
DIAGRAM OF A EUROPEAN STYLE CABINET FOR 3 PANEL STRINGS
1
Fuse per string
of panel
(on the + side)
1 Common bus
bar (on the - side)
ON/OFF
contactor
Surge
Protection
Device (SPD) /
Lightning arrestor
FIGURE 5:
EXAMPLE
OF A US STYLE CABINET
(same components than figure 4)
ON/OFF contactor
1 Common bar
(on the -)
1 Earth/Ground bar
(under the - bar)
1
Fuse per panel string
(on the +)
Lightning arrestor
Protection
cabinet
Solar pumping
inverter cabinet
ON/OFF contactor
lever
Internal view
External view