7
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation and Maintenance Guide
Priming the Pump
(continued)
10. Press ON/STOP
to start the pump.
The pump will begin to prime (if enabled) and ramp up to the programmed priming speed.
11. When a steady stream of water appears
from the air relief valve, close the valve.
12. Do not allow your pump to run longer than 30 minutes without successfully priming.
If the pump does not prime, check your priming
settings or refer to
TROUBLESHOOTING, page 19
.
Default Settings
If the pump is started using the ON/STOP button before a customized
schedule is programmed, the pump will run
the default Program 1 schedule (24 hours at 30 GPM). The Quick Clean button can be used
to temporarily override
this default Program 1 schedule. Default programs can be edited via the Pentair Home app or the using the optional
touchsreen.
Restore System Defaults
Restoring system defaults will delete all custom programs and restore all default settings and programs. Network
settings and the security PIN (if enabled) will be retained. This can be
done via the Pentair Home App, drive controls, or
optional touchscreen controller.
To restore system
defaults using drive controls, disable the pump then press and hold both the CONNECT and QUICK
CLEAN buttons for 3 seconds.
Factory Reset
A factory reset erases
all user-entered information, including custom programs,
security PIN, and network settings. All
programs will be restored to factory defaults. A factory reset can only be performed using the drive controls.
To perform a factory reset, disable the pump then press and hold all three buttons for 3 seconds.
Dostları ilə paylaş: