Ladder
Diagram
to
perform
this
operation
Program Description
RUNG000 is Master Start and Stop the process.
RUNG001 operates Conveyor Motors with address O:2/0 to start moving parts to other process. This is
started as soon as Start PB I:1/14 is pressed.
RUNG002 comprises Up Counter which counts the number of parts detected
by the detector which is
connected to I:1/0.
Whenever a part is detected, I:1/0 goes high incrementing accumulator value of C5:0
Counter.
When 1000 parts are counted, done bit is generated which is used to operate Solenoid Coil in RUNG003. It
allows the current to pass and solenoid is operated.
Assuming that it takes 2secs to divert the part for quality check, 2secs of timer T4:0 is used. This timer bit
T4:0/DN resets the counter value to 0 which in turn unlatches solenoid coil O:2/1 taking gate to its main position.