9-12 Nisan 2011 İstanbul Üniversitesi



Yüklə 5,01 Kb.
Pdf görüntüsü
səhifə31/48
tarix31.03.2017
ölçüsü5,01 Kb.
#12921
1   ...   27   28   29   30   31   32   33   34   ...   48

 
Anahtar Kelimeler: Uzun süreli potansiyasyon, Hipokampüs, Soğuk stres, Kortikosteron
 
 
The effect of exposure to mild cold on hippocampal long term potentiation in the 
dentate gyrus of rats 
 
OBJECTIVES:  Stress  impairs  long  term  potentiation  (LTP)  in  the  hippocampus.  The  majority  of  the  studies 
performed in the CA1 field of the hippocampus, in vitro. The mechanisms underlying the stress related effects 
are still controversial. Corticosterone has received most attention to date. We aimed to investigate the impacts 
of mild cold exposure on hippocampal LTP induction in rats. 
MATERIALS & METHODS: Experimental procedures were approved by the Institutional Animal Care and Use 
Committee  of  Erciyes  University.  Rats  were  randomly  assigned  either  to  control  or  acute  (ACS)  and  chronic 
(CCS) cold exposed groups. The control rats stayed in their home cages, while the experimental animals were 
subjected  to  a  2  h  period  of  cold  exposure  (4°C).  This  procedure  was  performed  only  once  for  ACS  group, 
whereas repeated for 21 days for CCS group. Right after the cold exposure, blood samples were collected for 
assessment of plasma corticosterone levels and LTP recordings were taken. 
RESULTS:  Potentiations  of  the  population  spike  (PS)  amplitude  and  field  excitatory  postsynaptic  potentials 
(fEPSP)  slope  in  ACS group were  not  statistically  different  from  those  of  control  (p>0.05).  There  was  also  no 
difference between the CCS and control rats, except the fEPSP slope measured in the induction phase (p<0.05) 
and PS amplitude measured in the maintenance phase (p<0.05). Plasma corticosterone levels in ACS and CCS 
groups were higher than the control (p<0.05, for each). 
CONCLUSION: Our results indicate that rewarming following acute cold stress may improve LTP response, but 
chronic exposition might deteriorate the electrophysiological sign of working memory. 
 
Keywords: Long term potentiation, Hippocampus, Cold stress, Corticosterone 

Poster Bildiriler / Poster Presentations 
159 
 
P66 
 
Görsel kortekste doğrusallık dışı hemodinamik yanıtlardaki sinirsel 
mekanizmanın incelenmesi 
 
Sinem Burcu Erdoğan
1
, Adil Deniz Duru
1
, Itır Kaşıkçı
2
, Elif Kurt
2
, Ahmet Ademoğlu
1
, Tamer 
Demiralp
3
 
 
1
Boğaziçi Üniversitesi, Biyomedikal Mühendisliği Enstitüsü, İstanbul  
2
İstanbul Üniversitesi, Deneysel Tıp Araştırma Enstitüsü, Sinirbilim Anabilim Dalı, İstanbul 
3
İstanbul Üniversitesi, İstanbul Tıp Fakültesi, Fizyoloji Anabilim Dalı, İstanbul 
  
1
Bogazici University, Institute of Biomedical Engineering, Istanbul, Turkey 
2
Istanbul University, Institute of Experimental Medicine, Neuroscience Department, Istanbul, Turkey 
3
Istanbul University, Istanbul Medical Faculty, Physiology Department, Istanbul, Turkey 
 
AMAÇ:  İşlevsel  manyetik  rezonans  görüntüleme  (iMRG)  yöntemi  ile  elde  edilen  doku  oksijenlenme  seviyesine 
bağlı  (BOLD)  hemodinamik  cevaplarının  doğrusallık  dışı  özelliği;  bir  çok  olaya  bağlı  iMRG  deney  çalışmasında 
gözlenmiştir.  Bu  durumun  daha  önceki  çalışmalarda  ayrıntıyla  incelenmiş  olmasına  rağmen,  altında  yatan 
sebebin sinirsel temelli olma ihtimali tam olarak açıklanamamıştır. Çalışmamızın amacı; hemodinamik yanıtların 
doğrusal olmamasının altında yatan sinirsel mekanizmayı incelemektir. 
GEREÇ  ve  YÖNTEM:  Çalışmamızda  alfa  bandında  verilen  görsel  uyarım  frekansları  (6Hz,  8Hz,  10Hz,  12Hz) 
sırasında  insandan  alınan  eş  zamanlı  EEG-iMRG  kayıtları  yardımıyla  elektrofizyolojik  ölçümler  ve  vasküler 
dinamikler arasındaki bağıntı incelenmiştir. Friston ve arkadaşlarının hemodinamik modelinde açıklanan, nöronal 
aktivitenin  vasküler  girdiye  dönüşme  verimliliğini  yansıtan    ''verimlilik''  parametresi  (Friston  ve  arkadaşları, 
2000);  EEG  bilgisi  kullanılarak  elde  edilen  iMRG  haritalarında  Bayes  çıkarımı  kullanılarak  hesaplanmıştır. 
BULGULAR:  Gerek  EEG  kaynak  görüntülerinden,  gerekse  BOLD  yanıtlarından  elde  edilen  ortalama  genlikler 
uyarım frekansına bağlı olarak doğrusallık dışı bir değişim göstermektedir. Ancak, görsel korteksteki elektriksel 
kaynakların  ortalama  güç  değişimlerinin  tepe  noktaları  ile  ''verimlilik''  parametresi  arasında  doğrusal  bir  ilinti 
bulunmuştur (R
2
=0.89, p<0.05). 
SONUÇ:  Elde  edilen  sonuçlar,  EEG  ve  iMRG  işaretlerinin  büyük  ölçeklerde  tutarlı  olduğuna  işaret  etmektedir. 
Bulgular  gözlemlediğimiz  hemodinamik  cevapların  doğrusallık  dışı  özelliklerinin;  temelde  yatan  sinirsel 
mekanizmanın  doğrusallık  dışı  özelliğini  yansıttığına  işaret  etmektedir.  Nörovasküler  bağıntıyı  açıklayan 
dönüşüm  işlevinin;  hızlı  dinamiklere  sahip  sinirsel  etkinliği  düşük  dinamikli  vasküler  girdiye  dönüştüren  alçak-
geçirgen bir süzgeç davranışı gösterdiği düşünülmektedir. 
 
Anahtar Kelimeler: EEG, iMRG, Nörovasküler eşleşme, Hemodinamik yanıt 
 
Investigation of the neural meachanisms underlying hemodynamic response 
nonlinearity in the primary visual cortex 
 
OBJECTIVES: It has been well accepted that the nonlinear hemodynamic responses of the blood oxygenation 
level  dependent  (BOLD)  functional  MRI  (fMRI)  are  important  and  widely  present  in  a  series  of  experimental 
paradigms  especially  for  event-related  fMRI.  Although  this  phenomenon  has  been  intensively  studied  and  the 
post-capillary  venous  expansion  has  been  found  to  be  an  intrinsically  nonlinear  mechanical  process,  the 
existence of a possible neural basis for the nonlinearity has not been clearly shown. The aim of this study is to 
investigate  the  neural  mechanism  underlying  hemodynamic  response  nonlinearity  in  a  series  of  visual 
stimulation frequencies. 
MATERIALS & METHODS: In this study, we assessed the correlation between electrical and vascular indices 
by  performing  simultaneous  electroencephalography  (EEG)  and  fMRI  recordings  in  humans  during  a  series  of 
visual stimulation frequencies (6 Hz, 8Hz, 10 Hz, 12 Hz).  
RESULTS: Both event-related potentials and hemodynamic responses show nonlinear behaviors with changes 
of  stimulation  frequencies.  However;  the  peak  changes  of  mean  powers  of  brain  electrical  sources  and  the 
neuronal  efficacies  (as  originally  described  in  the  hemodynamics  model  [Friston  et  al.  Neuroimage,  12,  466-
477, 2000] ) which represent the vascular inputs in primary visual cortex consistently show a linear correlation 
(R
2
=0.89, p<0.05). 
CONCLUSION: The hemodynamic response nonlinearity found in this study primarily reflects the nonlinearity 
of underlying neural activity. The results imply that EEG and fMRI signals are consistent at a large scale. The 
transferring function of neurovascular coupling is likely a low pass filter which transduces the fast dynamics of 
neural activity into a vascular input of slow dynamics. 
 
Keywords: EEG, fMRI, Neurovascular coupling, Hemodynamic response 

Poster Bildiriler / Poster Presentations 
160 
 
P67 
 
Bilişsel etkinliği ile takip eden dinlenme süreçlerinde İşlevsel Bağlantısallığın 
değişimi  
 
Bilge Aksu
1
, Ata Akın

 
1
Boğaziçi Üniversitesi, Elektronik Mühendisliği Bölümü, İstanbul 
2
Boğaziçi Üniversitesi, Biyomedikal Mühendisliği Enstitüsü, İstanbul 
 
1
Bogazici University, Dept. Of Electronics Engineering, Istanbul, Turkey 
2
Bogazici University, Institute of Biomedical Engineering, Istanbul, Turkey 
 
AMAÇ:  İşlevsel  bağlantısallığın  dinlenme  ve  etkinlik  anlarındaki  değişiminin  fNIRS  yöntemi  ile  ölçülmesi  ile, 
etkinliği  takip  eden  dinlenme  anlarındaki  dinlenik  durum  işlevsel  bağlantısallığın  öncesindeki  etkinlikten  nasıl 
etkilendiğini incelemek. 
GEREÇ ve YÖNTEM: Prefrontal korteksin 16 değişik bölgesindeki hemodinamik değişimler araasındaki işlevsel 
bağlantısallığı  ölçmek  için  17  yetişkin  sağlıklı  deneğe  kelime-renk  eşleştirilmiş  Stroop  deneyi  uygulandı  ve  bu 
esnada fNIRS sistemi ile ölçümler alındı. Her deneğe ait fNIRS oksihemoglobin verilerinden Nötral (N), Eşleşik 
(C)  ve  Eşleşik  olmayan  (IC)  uyaranlara  karşı  oluşan  bağlantısallık,  bu  uyarımları  takip  eden  dinlenme 
periyotlarındaki  bağlantısallıkla  karşılaştırıldı.  Her  kanala  ait  bağlantısallık  Gauss-Markov  AR-1  modeliyle 
hesaplandı. MNLS (minimum norm en küçük kareler) yöntemi ile değişik kanallar arasındaki bağlılık bulundu ve 
16x16 bir bağlılık matriksiyle gösterildi. Her bir denek için elde edilen bu matriksler sonra da temporal bağlılığı 
ölçmek için ITM (veri transfer metriği) adında bir metrikte kullanıldı. Bu 17 ITM sonucunun ortalaması alındı ve 
iki  kuyruklu  T-test  kullanıldı.  Sonuçta,  N,C,IC  dinlenme  periyotlarında  elde  edilen  ortalama  ITM  2  boyutlu 
grafikle görselleştirildi. 
BULGULAR:  Artan  bilişsel  yük  ile  beyindeki  işlevsel  bağlantısallığın  arttığı  daha  önce  gösterilmişti.  Bizim 
çalışmamızda,  değişik  uyaranların  dinlenme  periyotlarında  da  uyaranda  olduğu  gibi  benzer  bir  artış  yaşandığı 
gösterildi.  Şöyle  ki,  N,C  ve  IC  tipi  uyaranlarda  ortalama  ITM  0.57,  0.61,  0.63,  ve  bu  uyaranların  dinlenme 
periyotlarındaki değerlerinin 0.57, 0.60, 0.61 olduğu bulundu. 
SONUÇ:  İşlevsel  bağlantısallığı  hesaplamak  için  geliştirdiğimiz  bu  yöntem  ile  dinleme  anlarındaki 
bağlantısallığın,  hemen  öncesindeki  etkinlikle  çok  etkilendiğini  gördük.  Özellikle  yoğun  bilişsel  etkinliği  takip 
eden  dinlenme  anlarında  da  işlevsel  bağlantısallık  yüksek  çıktı.  Bu  da  beynin  hemen  dinlenmeye  geçmediğini 
gösteren fizyolojik bir bulgu oldu. 
 
Anahtar Kelimeler: fNIRS, İşlevsel bağlantısallık, Dinlenme anı bağlantısallık
 
 
Functional connectivity during cognitive activity and the rest episodes following 
activity 
 
OBJECTIVES:  Computation  of  the  functional  connectivity during  cognitive  activity  and rest  via fNIRS  method 
and investigate the influence of the load of cognitive activity on the connectivity of rest episodes. 
MATERIALS & METHODS: Color-word matching Stroop task is used to investigate the functional connectivity 
by  measuring  the  hemodynamic  changes  at  PFC  via  fNIRS  from  17  healthy  adults.  Connectivity  of  fNIRS 
Oxyhemoglobin data for the Neutral (N), Congruent (C) and Incongruent (IC) stimuli are compared against the 
rest  periods  following  each  type  of  stimuli.  The  connectivity  between  each  channel  is  calculated  by  a  Gauss-
Markov  AR-1  model.  The  MNLS  (minimum  norm  least  squares)  approach  is  used  to calculate  the  connectivity 
between  different  channels  and  these values  are represented  by  a 16x16  connectivity matrix.  These  matrices 
specific to each subject are further used to measure temporal connectivity by a metric called ITM, information 
transfer metric. The averages of these 17 ITM results are taken for each type of question and two-tailed T test 
is used. At the end, for N,C,IC rest periods, average ITM is visualized on a 2D graph. 
RESULTS:  It  was  already observed  that  the  functional  connectivity  of  the brain  increases  with  the  increasing 
cognitive load. In our work, it was shown that the functional connectivity during the rest periods undergoes the 
same changes as in stimulus connectivity. Specifically the average ITMs for N, C and IC stimuli were found as 
0.57, 0.61, 0.63, and for the corresponding rest times, it was found that these values are 0.57, 0.60, 0.61. 
CONCLUSION:  We observed that the metric we developed to compute the functional connectivity confirms a 
direct  influence  of  the  connectivity  at  rest  following  cognitive  activity.  Connectivity  at  rest  following  heavy 
cognitive activity is found to be high. This confirms that the brain requires longer time to achieve a rest state 
after heavy cognitive activity. 
  
Keywords: fNIRS, Functional connectivity, Resting connectivity 

Poster Bildiriler / Poster Presentations 
161 
 
P68 
 
3T MR’da alınmış eşzamanlı EEG-fMRG kayıtlarında birleşik artifakt 
temizleme yöntemlerinin karşılaştırılması 
 
Sinem Kara
1
, Basri Erdoğan
2
, Tamer Demiralp
3
, Letizia Leocani
1
, Giancarlo Comi

  
1
San Raffaele Eğitim ve Araştırma Hastanesi, Deneysel Nöroloji Enstitüsü, Milano, İtalya 
2
Boğaziçi Üniversitesi, Biyomedikal Mühendisliği Enstitüsü, İstanbul 
3
İstanbul Üniversitesi, İstanbul Tıp Fakültesi, Fizyoloji Anabilim Dalı, İstanbul 
 
1
Università Vita-Salute IRCCS San Raffaele, Experimental Neurology Institute, Milan, Italy 
2
Bogazici University, Biomedical Engineering Institute, Istanbul, Turkey 
3
Istanbul University, Istanbul Medical Faculty, Department of Physiology, Istanbul, Turkey 
 
AMAÇ:  fMRG’yle  eşzamanlı  alınan  EEG  verilerinde  meydana  gelen  gradyen  (GA)  ve  balistokardiyogram  (BKA) 
artifaktları büyük oranda sorun yaratmaktadır. OAÇ, OKS ve BBA bu artifaktların temizlenmesi için kullanılan en 
yaygın  yöntemlerdir.  Biz  bu  yöntemleri  çalışmamızda  OAÇ+BBA  (OAÇBBA)  ve  OTK+BBA  (OTKBBA)  olarak 
birleştirip, 3T MR’da bir yüz işlemleme ödevinden kaydedilen EEG/fMRG yanıtları üzerinde karşılaştırdık.  
GEREÇ ve YÖNTEM: Her iki yöntemde de GA temizliği için Allen algoritması ve 0.5-40 Hz filtresi uygulandıktan 
sonra BKA’nın temizlenmesi hedeflendi. BKA temizliğinin ilk aşaması olarak OAÇ ve OKS ayrı ayrı uygulandıktan 
sonra  ikinci  aşama olarak göz  artifaktları,  GA ve  BKA  artklarının  temizlenmesi  için  OAÇ  veya OKS  uygulanmış 
verilerin tamamına BBA uygulandı. Artifakt temizliğinin niteliği (1) tek-dilim ERP varyansı ve (2) EKG spektrum 
tepelerindeki bağıl EEG gücü ile değerlendirildi.  
BULGULAR:  İlk  değerlendirme  için  olaya  kilitli  dilimler  uyaran  öncesi  temel  aktiviteye  göre  düzeltildi, 
dilimlerdeki  her  bir  kanal  için  uyaran  sonrası  aralıktaki  noktaların  standart  sapması  hesaplandı  ve  ortalaması 
alındı.  İkinci  değerlendirmede  EKG  kanalının  temel  frekans  ve  4  harmoniği  belirlendi.  Bu  beş  spektral  EEG 
tepesinin toplamı 0.25-12 Hz aralığındaki total EEG gücüne bölündü. Tek-epok OİP varyansında kontrol koşulu 
ve diğer iki yöntem arasında fark anlamlı  iken (p<0.001) OAÇBBA ve OTKBBA arasındaki fark anlamlı değildi. 
EKG  spektrum  tepelerindeki  bağıl  EEG  gücü  OAÇBBA  yönteminde  OTKBBK’den  anlamlı  derecede  küçüktü 
(p<0.001). 
SONUÇ:  Karşılaştırmalardan  en  azından  bir  tanesi  OAÇBBK  performansının  OTKBBK’nınkinden  daha  iyi 
olduğunu göstermektedir. 
 
Anahtar  Kelimeler:  Elektroensefalografi  (EEG)  -  Fonksiyonel  manyetik  rezonans  görüntüleme  (fMRG), 
Ortalanmış artifaktın çıkartılması (OAÇ), Optimal temel küme (OTK), Bağımsız bileşenler analizi (BBA) 
 
Comparison of combined artifact correction methods for simultaneously 
recorded EEG-fMRI in a 3T MR system 
 
OBJECTIVES:  EEG  data  collected  during  fMRI  suffers  basically  from  gradient  (GA)  and  ballistocardiogram 
artifacts (BCG). Here we compare most commonly used artifact removal methods in a combined form as AAS + 
ICA (AASICA) and OBS + ICA (OBSICA).  
MATERIALS  &  METHODS:  The  EEG  data  was  recorded  during  a  face  processing  task  in  a  3T-MR.    For  both 
methods,  firstly  GA  cleaning  by  Allen’s  algorithm  and  a  0.5-40  Hz  band-pass  filter  was  carried  out.  The  first 
stage of both methods aimed to correct BCGs through AAS or OBS, while the ICA in the second stage aimed to 
correct the residual GAs, BCGs and ocular artifacts (OA). As control we applied ICA to only GA corrected data 
for correcting OAs only. The quality of the artifact correction was assessed by (1) single-trial ERP variance and 
(2) the relative EEG power at ECG spectral peaks.  
RESULTS:  For  the  1
st
  comparison  event-locked  epochs  were  baseline  corrected,  standard  deviation  over  the 
trials  was  computed  and  averaged  over  time  points  of  the  post-stimulus  period  and  channels.  For  the  2
nd
 
comparison  the  sum  of  the  first  five  EEG  spectral  peaks  on  ECG  channel  was  divided  by  the  total  EEG  power 
between 0.25-12 Hz. Single-trial ERP variance showed significant difference between the control condition and 
the  other  two  methods  (p<0.001)  without  a  significant  difference  between  AASICA  and  OBSICA,  while  the 
relative EEG power at ECG spectral peaks was significantly smaller in AASICA technique compared with OBSICA 
(p<0.001).  
CONCLUSION: At least one of the comparisons suggests that AASICA performs better than OBSICA. 
 
Keywords:  Electroencephalography  (EEG)  -  Functional  magnetic  resonance  imaging  (fMRI),  Average  artifact 
subtraction (AAS), Optimum basis set (OBS), Independent component analysis (ICA) 

Poster Bildiriler / Poster Presentations 
162 
 
P69 
 
Beyin-makine arabirimleri için düşük maliyetli mikroelektrot dizisi 
 
Mehmet Kocatürk
1
, Halil Özcan Gülçür
1
, Reşit Canbeyli
2
 
 
1
Boğaziçi Üniversitesi, Biyomedikal Mühendisliği Enstitüsü, İstanbul 
2
Boğaziçi Üniversitesi, Fen-Edebiyat Fakültesi Psikoloji Bölümü, İstanbul 
 
1
Boğaziçi University, Biomedical Engineering Institute, Istanbul, Turkey 
2
Boğaziçi University, Faculty of Arts and Sciences, Psychology Department, Istanbul, Turkey 
 
AMAÇ: Beyin-makine arayüzleri (BMA) implante mikroelektrot dizileri (MED) ile ölçülen merkezi veya periferik 
sinir  sistemine  ait  beyin  aktivitesini  deşifre  etmek  ve  doğrudan  bir  bilgisayarı,  protez  uzvu,  robotu  kontrol 
edecek  veya  felçli  kasların  kullanılmasını  sağlayacak  komutları  üretmek  için  kullanılmaktadır.  Sıçan  motor 
korteksi üzerindeki BMA araştırmalarımız için kendi veri toplama ve gerçek-zamanlı iğnecik ayıklama sistemimizi 
geliştirdik  ve  gereken  özel  8  kanallı  mikroelektrot  dizilerini  ürettik.  Ayrıntılar  ve  dizilerin  üretim  yöntemi  bu 
bildiride tanıtılmaktadır. 
GEREÇ  ve  YÖNTEM:  MEDler  çoğunlukla  VLSI  imalatından  uyarlanan  teknolojiler  kullanılarak  üretilmektedir. 
Silikon tabanlı iki ya da üç boyutlu, değişik esneklikte, prob çapı birkaç mikronu geçmeyen MEDler ticari olarak 
üretilmiştir. Ancak bunlar pahalı ve amacımız için tam olarak uygun olmadığından kendi elektrodlarımızı yapma 
yolunu  seçtik.  Elektrotların  imalatı  için,  teflon  yalıtımlı,  %90  Platin,  %10  iridyum  alaşımından  yapılmış  25 
mikron  çapında  mikrotel  kullandık.  Teller  kesilip,  doğrultulduktan  sonra  çelik  bir  şablon  (genişlik:  50  mikron, 
aralığı:  250  mikron)  kullanılarak  yivler  içine  yerleştirildi.  Diş  akriliği  ile  tespit  edildikten  sonra  küçük  bir  baskı 
devre üzerindeki özel bir konnektöre lehimlenerek üretim tamamlandı. 
BULGULAR:  Hazırlanan  mikrotel  dizisinin  implantasyondan  sonraki  empedans  aralığı  1.7-1.9  MΩ  olarak 
ölçülmüştür  (500  Hz  kare  dalga).  Hazırlanan  mikrotel  dizisinin  sıçan  motor  korteksi  5.  katmanından  üç  aya 
kadar kronik kayıt almayı mümkün hale getirdiği gözlenmiştir.  
SONUÇ: Bu teknikle deneyimli bir araştırmacı 3-4 saat içerisinde 250 mikron aralıklı 8 kanallı bir mikroelektrot 
dizisini kullanıma hazır hale getirebilmektedir. Bu mikroelektrot dizisinin maliyeti 15 dolar civarındadır.  
 
Anahtar Kelimeler: Hücredışı kayıt alma, Mikroelektrot dizisi, Elektrofizyoloji yöntemi 
 
Boğaziçi  Üniversitesi  Hayvan  Deneyleri  Yerel  Etik  Kurulu  (BÜHADYEK)  tarafından  onaylanmıştır.  Boğaziçi 
Üniversitesi BAP Koordinasyon Birimi tarafından desteklenmiştir (Proje numarası: 5155).
 
 
A low-cost microelectrode array for brain-machine interfacing 
 
OBJECTIVES:  Brain-machine  interfaces  (BMIs)  decipher  brain  activity  from  the  central  or  peripheral  nervous 
system measured via implanted microelectrode arrays (MEAs) and generate appropriate commands to directly 
control  a  computer,  a  prosthetic  limb,  a  robot,  etc.  or  provide  the  electrical  signals  that  enable  the  use  of 
paralyzed  muscles.  We  have  developed  our  own  neural  data  acquisition  and  online  spike  sorting  system  and 
fabricated  8-channel  microelectrode  arrays  for  our  BMI  research  on  rat  motor  cortex.    The  details  and  the 
fabrication methodology of the arrays are presented in this paper.  
MATERIALS  &  METHODS:  MEAs  have  been  manufactured  using  various  technologies,  mostly  adapted  from 
VLSI  manufacturing.  At  present  silicon-based  2D,  3D  rigid  and  flexible  MEAs  with  probe  diameters  not 
exceeding a few microns are commercially available. Since they are expensive and not exactly suitable for our 
purposes  we  made  our  own  MEAs.  For  fabricating  the  electrodes,  we  used  25  micron  microwire,  made  of  an 
alloy of 90% platinum, 10% iridium with Teflon insulation. Spooled wires were cut, straightened and put into 
chambers  using  a  steel  template  (width:  50  microns,  spacing:  250  microns).  After  fixing  with  dental  acrylic, 
they were soldered to a special connector attached to a small PCB. 
RESULTS:  The  impedance  range  of  the  microelectrode  array  was  measured  as  1.7-1.9  MΩ  (500  Hz,  square 
pulses).  It  is  observed  that  the  fabricated  microwire  array  enables  chronic  recordings  from  rat  motor  cortex 
Layer V up to three months.  
Yüklə 5,01 Kb.

Dostları ilə paylaş:
1   ...   27   28   29   30   31   32   33   34   ...   48




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©azkurs.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin