Laboratoriya ishining dasturi. 1. Transformatorni tashqi ko„rikdan o„tkazish.
2. Transformator chulg„amlarining izolyatsiya qarshiligini tekshirish.
Transformator chulg‟amlarining namlik darajasini aniqlash.
3. Transformatorning transformatsiya koeffitsientini barcha shahobchalar
bo„yicha aniqlash.
4. Transformator chulg„amlarining ulanish guruhlarini tekshirish.
5. Uch fazali transformatorning ulanish guruhlarini tekshirish.
Ishni bajarish tartibi.
1. Transformatorni ko„zdan kechiring. Pasport ma‟lumotlarini yozib oling.
2. Har bir chulg„amni yerga nisbatan hamda chulg„amlarga nisbatan
izolyatsiya qarshiligini o„lchang. O„lchash megommetr yordamida 1 minut
davomida amalga oshiriladi. Absorsiya koeffitsientini quyidagi ifoda orqali
aniqlang:
''
15
''
60
R R К ab
3. Transformator chulg„amining qarshiligini o„zgarmas tok orqali o„lchang.
O„lchashni har bir yuqori va pastki chulg„amlarda Vitson ko„prigi orqali amalga
oshiring. Transformator chulg„amlarining ulanish sxemasini chizing.
4. Har bir chulg„amlarora transformatorning transformatsiya koeffitsientini
aniqlang. Buning uchun 3.1-rasmni yig„ing. Transformatorning faqat yuqori
chulg„amiga 220 V kuchlanish berib va bir vaqtning o„zida yuqori va pastki
chulg„amlardagi kuchlanishlarni o„lchang.
O„lchash natijalarini 3.1-jadvalga kiriting.
3.1-jadval
T
ran
sf
o
r-
ma
-o
r
tu
ri
A-B
B-C
A-C
3
са bc аb K K K K
U
AB
U
ab
K
ab
U
BC
U
bc
K
bc
U
AC
U
ac
K
ac